IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

261

matching recommendations
Reset
NAICS 31182 Cookie, Cracker, and Pasta Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0156 # 01 Y:2009 01 2009 ADD AREA LIGHTING SWITCHES $10,860 $8,096 Implemented
IC0156 # 02 Y:2009 02 2009 INSTALL OCCUPANCY SENSORS $4,252 $4,247 Implemented
IC0156 # 03 Y:2009 03 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,116 $1,649 Implemented
IC0156 # 04 Y:2009 04 2009 DISCONNECT BALLASTS $2,089 $2,200 Implemented
IC0156 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,483 $29,250 Implemented
IC0156 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,309 $5,917 Implemented
IC0156 # 07 Y:2009 07 2009 DEVELOP A REPAIR/REPLACE POLICY $4,792 $15,044 Implemented
IC0156 # 08 Y:2009 08 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,513 $1,610 Not Implemented
IC0156 # 09 Y:2009 09 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $8,278 $7,995 Not Implemented
IC0156 # 10 Y:2009 10 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $934 $0 Implemented
IC0156 # 11 Y:2009 11 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $1,559 $2,887 Implemented
IC0156 # 12 Y:2009 12 2009 INSTALL TIMERS AND/OR THERMOSTATS $1,299 $0 Implemented
GT0861 # 01 Y:2009 01 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,115 $0 Not Implemented
GT0861 # 02 Y:2009 02 2009 USE MINIMUM SAFE OVEN VENTILATION $246,400 $5,600 Not Implemented
GT0861 # 03 Y:2009 03 2009 ADJUST BURNERS FOR EFFICIENT OPERATION $38,729 $40,000 Implemented
GT0861 # 04 Y:2009 04 2009 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,626 $0 Not Implemented
GT0861 # 05 Y:2009 05 2009 INSULATE BARE EQUIPMENT $98,000 $244,260 Implemented
GT0861 # 06 Y:2009 06 2009 INSULATE BARE EQUIPMENT $6,025 $951 Implemented
GT0861 # 07 Y:2009 07 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,257 $2,400 Not Implemented
GT0861 # 08 Y:2009 08 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,345 $17,129 Not Implemented
GT0861 # 09 Y:2009 09 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,933 $60,324 Not Implemented
GT0861 # 10 Y:2009 10 2009 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $83,157 $231,450 Not Implemented
NC0366 # 01 Y:2007 01 2007 RECOVER WASTE HEAT FROM EQUIPMENT $81,321 $400,000 Not Implemented
NC0366 # 02 Y:2007 02 2007 RECOVER WASTE HEAT FROM EQUIPMENT $61,491 $250,000 Not Implemented
NC0366 # 03 Y:2007 03 2007 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $18,013 $60,000 Not Implemented