Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
115
matching recommendationsNAICS | 3119 | Other Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0346 # 08 Y:2019 | 08 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $510 | $165 | Implemented |
MI0346 # 09 Y:2019 | 09 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $308 | $395 | Not Implemented |
UF0514 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,154 | $30,844 | Implemented |
UF0514 # 02 Y:2017 | 02 | 2017 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $7,847 | $20,000 | Implemented |
UF0514 # 03 Y:2017 | 03 | 2017 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,710 | $7,580 | Not Implemented |
UF0514 # 04 Y:2017 | 04 | 2017 | REDUCE EXCESS STEAM BLEEDING | $4,320 | $0 | Implemented |
UF0514 # 05 Y:2017 | 05 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,740 | $2,882 | Implemented |
UF0514 # 06 Y:2017 | 06 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,693 | $6,775 | Implemented |
UF0514 # 07 Y:2017 | 07 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,432 | $0 | Implemented |
UF0426 # 01 Y:2009 | 01 | 2009 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $20,276 | $4,000 | Not Implemented |
UF0426 # 02 Y:2009 | 02 | 2009 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $146,810 | $3,192 | Not Implemented |
UF0426 # 03 Y:2009 | 03 | 2009 | RECYCLE FLUORESCENT LAMPS | $328 | $3,405 | Not Implemented |
UF0426 # 04 Y:2009 | 04 | 2009 | INSTALL SKYLIGHTS | $2,555 | $238 | Implemented |
UF0426 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $1,764 | $481 | Not Implemented |
UF0426 # 06 Y:2009 | 06 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $50,000 | $25,000 | Not Implemented |
UF0426 # 07 Y:2009 | 07 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,382 | $2,382 | Not Implemented |
UF0426 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $234,287 | $67,220 | Not Implemented |
UF0426 # 09 Y:2009 | 09 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,528 | $628 | Implemented |
UF0426 # 10 Y:2009 | 10 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,591 | $568 | Not Implemented |
UF0426 # 11 Y:2009 | 11 | 2009 | INSTALL OCCUPANCY SENSORS | $24,539 | $0 | Not Implemented |
UF0426 # 12 Y:2009 | 12 | 2009 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $37,500 | $4,483 | Not Implemented |
UF0426 # 13 Y:2009 | 13 | 2009 | INSTALL COMMON HEADER ON COMPRESSORS | $229,898 | $0 | Not Implemented |
UF0426 # 14 Y:2009 | 14 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $1,083 | $0 | Not Implemented |
UF0426 # 15 Y:2009 | 15 | 2009 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $111,037 | $4,000 | Not Implemented |
MI0155 # 01 Y:2007 | 01 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $66,401 | $120,000 | Not Implemented |