Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,762
matching recommendationsNAICS | 3119 | Other Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0285 # 02 Y:2005 | 02 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $11,445 | $575 | Not Implemented |
MS0285 # 03 Y:2005 | 03 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,503 | $138 | Implemented |
MS0285 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,062 | $151 | Implemented |
MS0285 # 05 Y:2005 | 05 | 2005 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $671 | $972 | Not Implemented |
OR0493 # 01 Y:2005 | 01 | 2005 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $66,200 | $1,000 | Not Implemented |
OR0493 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,900 | $1,900 | Not Implemented |
OR0493 # 03 Y:2005 | 03 | 2005 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $5,400 | $1,000 | Not Implemented |
OR0493 # 04 Y:2005 | 04 | 2005 | USE OPTIMUM TEMPERATURE | $11,000 | $13,000 | Not Implemented |
OR0493 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,400 | $2,500 | Not Implemented |
OR0493 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,500 | $0 | Not Implemented |
OR0493 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $2,400 | $3,600 | Not Implemented |
OR0493 # 08 Y:2005 | 08 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,900 | $17,000 | Not Implemented |
WV0328 # 01 Y:2005 | 01 | 2005 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $89,602 | $72,720 | Not Implemented |
WV0328 # 02 Y:2005 | 02 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,992 | $0 | Not Implemented |
WV0328 # 03 Y:2005 | 03 | 2005 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,942 | $18,000 | Implemented |
WV0328 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,040 | $60 | Implemented |
WV0328 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $948 | $0 | Implemented |
WV0328 # 06 Y:2005 | 06 | 2005 | USE SYNTHETIC LUBRICANT | $649 | $30 | Not Implemented |
WV0328 # 07 Y:2005 | 07 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $646 | $278 | Implemented |
WV0328 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $406 | $430 | Not Implemented |
WV0328 # 09 Y:2005 | 09 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $397 | $120 | Implemented |
WV0328 # 10 Y:2005 | 10 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $282 | $1,530 | Implemented |
LE0216 # 01 Y:2005 | 01 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,847 | $1,200 | Not Implemented |
LE0216 # 02 Y:2005 | 02 | 2005 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,467 | $4,000 | Not Implemented |
LE0216 # 03 Y:2005 | 03 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,748 | $2,000 | Not Implemented |