Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
332
matching recommendationsNAICS | 31194 | Seasoning and Dressing Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0412 # 04 Y:2010 | 04 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,191 | $9,460 | Not Implemented |
WV0412 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,536 | $5,263 | Implemented |
WV0412 # 06 Y:2010 | 06 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,764 | $1,000 | Implemented |
WV0412 # 07 Y:2010 | 07 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,926 | $686 | Not Implemented |
WV0412 # 08 Y:2010 | 08 | 2010 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,795 | $0 | Implemented |
WV0412 # 09 Y:2010 | 09 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $480 | $284 | Not Implemented |
OR0556 # 01 Y:2010 | 01 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $542 | $0 | Implemented |
OR0556 # 02 Y:2010 | 02 | 2010 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,765 | $0 | Not Implemented |
OR0556 # 03 Y:2010 | 03 | 2010 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $8,900 | $8,900 | Implemented |
OR0556 # 04 Y:2010 | 04 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,987 | $5,125 | Not Implemented |
OR0556 # 05 Y:2010 | 05 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $3,131 | $2,861 | Implemented |
OR0556 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,320 | $2,320 | Implemented |
OR0556 # 07 Y:2010 | 07 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,397 | $11,734 | Not Implemented |
OR0556 # 08 Y:2010 | 08 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $16,479 | $65,003 | Not Implemented |
IC0168 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,051 | $66,738 | Implemented |
IC0168 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $365 | $0 | Implemented |
IC0168 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $1,372 | $3,624 | Implemented |
IC0168 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,400 | $419 | Implemented |
IC0168 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,327 | $29,969 | Implemented |
IC0168 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,166 | $0 | Implemented |
IC0168 # 07 Y:2010 | 07 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,111 | $0 | Implemented |
IC0168 # 08 Y:2010 | 08 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $2,615 | $800 | Implemented |
IC0168 # 09 Y:2010 | 09 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,934 | $1,949 | Implemented |
IC0168 # 10 Y:2010 | 10 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $16,738 | $18,200 | Implemented |
IC0168 # 11 Y:2010 | 11 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,965 | $1,265 | Implemented |