Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsNAICS | 311999 | All Other Miscellaneous Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0397 # 02 Y:2011 | 02 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $15,024 | $14,500 | Not Implemented |
BD0397 # 03 Y:2011 | 03 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,550 | $6,000 | Not Implemented |
BD0397 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $6,237 | $4,440 | Not Implemented |
BD0397 # 05 Y:2011 | 05 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,796 | $765 | Not Implemented |
BD0397 # 06 Y:2011 | 06 | 2011 | INSTALL TURBULATORS | $4,508 | $1,500 | Not Implemented |
BD0397 # 07 Y:2011 | 07 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,439 | $650 | Not Implemented |
BD0397 # 08 Y:2011 | 08 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,214 | $5,820 | Not Implemented |
BD0397 # 01 Y:2011 | 01 | 2011 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $23,085 | $6,000 | Not Implemented |
DL0066 # 05 Y:2011 | 05 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,701 | $1,257 | Not Implemented |
DL0066 # 07 Y:2011 | 07 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,163 | $3,750 | Not Implemented |
DL0066 # 06 Y:2011 | 06 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $12,600 | $10,000 | Not Implemented |
DL0066 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,015 | $4,000 | Implemented |
DL0066 # 03 Y:2011 | 03 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,460 | $2,000 | Implemented |
DL0066 # 02 Y:2011 | 02 | 2011 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $101,455 | $36,300 | Not Implemented |
DL0066 # 01 Y:2011 | 01 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,960 | $1,035 | Implemented |
IA0462 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,158 | $15,702 | Not Implemented |
IA0462 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,704 | $16,590 | Not Implemented |
IA0462 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $2,818 | $1,530 | Not Implemented |
IA0462 # 04 Y:2011 | 04 | 2011 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $59,656 | $20,000 | Not Implemented |
IA0462 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,983 | $25,000 | Not Implemented |
IA0462 # 06 Y:2011 | 06 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,698 | $240 | Not Implemented |
IA0462 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,593 | $250 | Not Implemented |
IA0462 # 08 Y:2011 | 08 | 2011 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $22,774 | $1,500 | Not Implemented |
IA0462 # 09 Y:2011 | 09 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,450 | $1,000 | Not Implemented |
IA0462 # 10 Y:2011 | 10 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,518 | $200 | Not Implemented |