Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,033
matching recommendationsNAICS | 3121 | Beverage Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0210 # 04 Y:2016 | 04 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $749 | $2,000 | Not Implemented |
MZ0210 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,903 | $1,150 | Implemented |
MZ0210 # 06 Y:2016 | 06 | 2016 | INSULATE BARE EQUIPMENT | $1,100 | $500 | Implemented |
MZ0210 # 07 Y:2016 | 07 | 2016 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $651 | $300 | Implemented |
MZ0210 # 08 Y:2016 | 08 | 2016 | INSTALL OCCUPANCY SENSORS | $3,340 | $375 | Not Implemented |
MZ0210 # 09 Y:2016 | 09 | 2016 | CONDENSE OPERATION INTO ONE BUILDING | $1,331 | $2,500 | Not Implemented |
MZ0210 # 10 Y:2016 | 10 | 2016 | RECYCLE WHITE WATER | $14,525 | $5,000 | Not Implemented |
MZ0210 # 11 Y:2016 | 11 | 2016 | INSULATE BARE EQUIPMENT | $625 | $850 | Not Implemented |
DL0157 # 01 Y:2016 | 01 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,140 | $0 | Implemented |
DL0157 # 02 Y:2016 | 02 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,860 | $2,250 | Not Implemented |
DL0157 # 03 Y:2016 | 03 | 2016 | TREAT AND REUSE RINSE WATERS | $34,545 | $41,405 | Implemented |
DL0157 # 04 Y:2016 | 04 | 2016 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $8,290 | $11,760 | Not Implemented |
DL0157 # 05 Y:2016 | 05 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $48,630 | $79,420 | Not Implemented |
DL0157 # 06 Y:2016 | 06 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,700 | $44,740 | Implemented |
DL0157 # 07 Y:2016 | 07 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,170 | $77,500 | Implemented |
DL0157 # 08 Y:2016 | 08 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,500 | $53,850 | Not Implemented |
DL0157 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,440 | $46,960 | Implemented |
SF0477 # 01 Y:2016 | 01 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,727 | $0 | Implemented |
SF0477 # 02 Y:2016 | 02 | 2016 | USE POWER DURING OFF-PEAK PERIODS | $1,528 | $0 | Not Implemented |
SF0477 # 03 Y:2016 | 03 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $22,945 | $0 | Implemented |
SF0477 # 04 Y:2016 | 04 | 2016 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $15,446 | $7,297 | Implemented |
SF0477 # 05 Y:2016 | 05 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,250 | $2,903 | Implemented |
SF0477 # 06 Y:2016 | 06 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $57,609 | $52,742 | Implemented |
SF0477 # 07 Y:2016 | 07 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $47,178 | $102,267 | Implemented |
SF0477 # 08 Y:2016 | 08 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,956 | $17,949 | Implemented |