Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

925

matching recommendations
Reset
NAICS 31211 Soft Drink and Ice Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0349 # 05 Y:2011 05 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $116 $195 Not Implemented
LL0349 # 06 Y:2011 06 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $83 $51 Not Implemented
UF0440 # 01 Y:2011 01 2011 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $43,145 $25,340 Not Implemented
UF0440 # 02 Y:2011 02 2011 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $3,404 $5,896 Not Implemented
UF0440 # 03 Y:2011 03 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,173 $1,818 Not Implemented
UF0440 # 04 Y:2011 04 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,370 $3,778 Not Implemented
UF0440 # 05 Y:2011 05 2011 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $28,580 $12,180 Not Implemented
UF0440 # 06 Y:2011 06 2011 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $136 $244 Not Implemented
UF0440 # 07 Y:2011 07 2011 INSTALL TURBULATORS $3,745 $3,750 Not Implemented
UF0440 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,493 $9,387 Not Implemented
UF0440 # 09 Y:2011 09 2011 INSTALL OCCUPANCY SENSORS $2,620 $243 Not Implemented
UF0440 # 10 Y:2011 10 2011 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $635 $0 Not Implemented
UF0440 # 11 Y:2011 11 2011 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,423 $840 Not Implemented
DL0064 # 01 Y:2011 01 2011 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $707 $100 Not Implemented
DL0064 # 02 Y:2011 02 2011 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $7,944 $5,080 Implemented
DL0064 # 03 Y:2011 03 2011 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $19,935 $20,500 Not Implemented
DL0064 # 04 Y:2011 04 2011 UPGRADE CONTROLS ON COMPRESSORS $7,030 $11,300 Implemented
MZ0056 # 01 Y:2010 01 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,032 $1,160 Not Implemented
MZ0056 # 02 Y:2010 02 2010 INSTALL OCCUPANCY SENSORS $4,969 $950 Not Implemented
MZ0056 # 03 Y:2010 03 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $2,784 $150 Not Implemented
MZ0056 # 04 Y:2010 04 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,352 $150 Not Implemented
MZ0056 # 05 Y:2010 05 2010 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $2,072 $1,000 Not Implemented
MZ0056 # 06 Y:2010 06 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,900 $0 Not Implemented
MZ0056 # 07 Y:2010 07 2010 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,340 $800 Not Implemented
MZ0056 # 08 Y:2010 08 2010 RECOVER WASTE HEAT FROM EQUIPMENT $99,250 $80,000 Not Implemented