Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
40
matching recommendationsNAICS | 31211 | Soft Drink and Ice Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0596 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $910 | $5,740 | Implemented |
CO0596 # 01 Y:2006 | 01 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $244 | $1,008 | Implemented |
CO0596 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,270 | $33,120 | Implemented |
CO0596 # 03 Y:2006 | 03 | 2006 | INCREASE EFFICIENCY OF TRUCKS | $5,740 | $0 | Implemented |
CO0596 # 04 Y:2006 | 04 | 2006 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,810 | $1,000 | Implemented |
CO0596 # 05 Y:2006 | 05 | 2006 | ADD AREA LIGHTING SWITCHES | $2,410 | $100 | Not Implemented |
CO0596 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,120 | $9,260 | Implemented |
CO0596 # 07 Y:2006 | 07 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,100 | $2,950 | Not Implemented |
TA0130 # 03 Y:2006 | 03 | 2006 | OPTIMIZE PLANT POWER FACTOR | $10,795 | $22,000 | Implemented |
TA0130 # 02 Y:2006 | 02 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $81 | $252 | Implemented |
TA0130 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,192 | $0 | Implemented |
BD0316 # 02 Y:2006 | 02 | 2006 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $4,724 | $1,200 | Implemented |
BD0316 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $679 | $2,102 | Implemented |
BD0316 # 04 Y:2006 | 04 | 2006 | INSTALL OCCUPANCY SENSORS | $1,033 | $675 | Implemented |
BD0316 # 03 Y:2006 | 03 | 2006 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $13,153 | $8,363 | Implemented |
BD0316 # 01 Y:2006 | 01 | 2006 | USE SYNTHETIC LUBRICANT | $7,871 | $800 | Not Implemented |
UF0388 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,746 | $4,846 | Not Implemented |
UF0388 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,378 | $1,688 | Not Implemented |
UF0388 # 03 Y:2006 | 03 | 2006 | INSTALL OCCUPANCY SENSORS | $341 | $342 | Not Implemented |
UF0388 # 04 Y:2006 | 04 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $922 | $2,346 | Not Implemented |
UF0388 # 05 Y:2006 | 05 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,286 | $1,238 | Not Implemented |
UF0388 # 06 Y:2006 | 06 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,957 | $0 | Not Implemented |
UF0388 # 07 Y:2006 | 07 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $193 | $374 | Not Implemented |
UF0388 # 08 Y:2006 | 08 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,088 | $93 | Not Implemented |
UF0388 # 09 Y:2006 | 09 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,663 | $1,320 | Not Implemented |