Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
451
matching recommendationsNAICS | 312111 | Soft Drink Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0717 # 01 Y:2013 | 01 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $21,124 | $14,700 | Not Implemented |
MA0717 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,036 | $8,700 | Not Implemented |
MA0717 # 04 Y:2013 | 04 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,986 | $5,700 | Implemented |
MA0717 # 02 Y:2013 | 02 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,293 | $8,275 | Implemented |
MA0717 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,679 | $4,082 | Implemented |
AM0641 # 08 Y:2013 | 08 | 2013 | USE SYNTHETIC LUBRICANT | $1,980 | $0 | Not Implemented |
AM0641 # 07 Y:2013 | 07 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,940 | $220 | Not Implemented |
AM0641 # 06 Y:2013 | 06 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,580 | $500 | Implemented |
AM0641 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,130 | $610 | Implemented |
AM0641 # 03 Y:2013 | 03 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,894 | $31,100 | Implemented |
AM0641 # 02 Y:2013 | 02 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $45,620 | $50,000 | Implemented |
AM0641 # 01 Y:2013 | 01 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $81,000 | $40,000 | Implemented |
AM0641 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $4,800 | $1,800 | Implemented |
SD0471 # 10 Y:2013 | 10 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $1,926 | $200 | Implemented |
SD0471 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,126 | $3,300 | Implemented |
SD0471 # 02 Y:2013 | 02 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $277,284 | $353,400 | Not Implemented |
SD0471 # 03 Y:2013 | 03 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $92,696 | $131,400 | Not Implemented |
SD0471 # 05 Y:2013 | 05 | 2013 | UPGRADE OBSOLETE EQUIPMENT | $34,337 | $110,000 | Not Implemented |
SD0471 # 09 Y:2013 | 09 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,810 | $18,500 | Not Implemented |
SD0471 # 04 Y:2013 | 04 | 2013 | REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE | $79,351 | $96,000 | Not Implemented |
SD0471 # 01 Y:2013 | 01 | 2013 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $629,471 | $234,900 | Not Implemented |
SD0471 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $23,316 | $500 | Not Implemented |
SD0471 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,423 | $100,248 | Implemented |
OK0840 # 09 Y:2013 | 09 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,770 | $21,632 | Not Implemented |
OK0840 # 11 Y:2013 | 11 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,220 | $3,650 | Not Implemented |