Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

449

matching recommendations
Reset
NAICS 31213 Wineries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0227 # 03 Y:2006 03 2006 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $209 $0 Not Implemented
SU0227 # 04 Y:2006 04 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,581 $2,035 Not Implemented
SU0227 # 05 Y:2006 05 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $11,968 $1,970 Not Implemented
SU0227 # 06 Y:2006 06 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,737 $496 Not Implemented
SU0227 # 07 Y:2006 07 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $629 $228 Implemented
SU0227 # 08 Y:2006 08 2006 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $2,257 $1,220 Not Implemented
SU0227 # 09 Y:2006 09 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $725 $1,187 Implemented
SU0227 # 10 Y:2006 10 2006 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $607 $1,187 Not Implemented
SU0227 # 11 Y:2006 11 2006 INSTALL OCCUPANCY SENSORS $91 $194 Implemented
SU0227 # 12 Y:2006 12 2006 OPTIMIZE PLANT POWER FACTOR $1,520 $13,971 Not Implemented
SF0288 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $220 $204 Not Implemented
SF0288 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,407 $1,649 Not Implemented
SF0288 # 03 Y:2004 03 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $481 $380 Not Implemented
SF0288 # 04 Y:2004 04 2004 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $842 $1,252 Not Implemented
SF0288 # 05 Y:2004 05 2004 INSTALL OCCUPANCY SENSORS $1,425 $2,689 Not Implemented
SF0288 # 06 Y:2004 06 2004 INSULATE BARE EQUIPMENT $334 $1,065 Implemented
SF0288 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $283 $925 Not Implemented
SF0288 # 08 Y:2004 08 2004 INSTALL SKYLIGHTS $954 $5,520 Not Implemented
SF0288 # 09 Y:2004 09 2004 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $6,105 $10,964 Not Implemented
SF0286 # 01 Y:2004 01 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $522 $0 Implemented
SF0286 # 02 Y:2004 02 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $871 $1,109 Not Implemented
SF0286 # 03 Y:2004 03 2004 INSULATE BARE EQUIPMENT $1,697 $829 Implemented
SF0286 # 04 Y:2004 04 2004 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,389 $20,000 Not Implemented
SF0286 # 05 Y:2004 05 2004 INSTALL OCCUPANCY SENSORS $2,363 $7,431 Not Implemented
SF0286 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $914 $4,363 Implemented