Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
77
matching recommendationsNAICS | 313 | Textile Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0457 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,771 | $10,041 | Implemented |
LE0457 # 05 Y:2018 | 05 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,689 | $13,000 | Implemented |
LE0457 # 04 Y:2018 | 04 | 2018 | REPLACE BOILER | $33,772 | $150,000 | Not Implemented |
LE0457 # 06 Y:2018 | 06 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,457 | $36,000 | Implemented |
LE0450 # 02 Y:2018 | 02 | 2018 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $16,243 | $8,000 | Not Implemented |
LE0450 # 08 Y:2018 | 08 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,463 | $22,000 | Not Implemented |
LE0450 # 06 Y:2018 | 06 | 2018 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $3,038 | $8,000 | Not Implemented |
LE0450 # 03 Y:2018 | 03 | 2018 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,802 | $3,000 | Not Implemented |
LE0450 # 01 Y:2018 | 01 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,167 | $1,000 | Not Implemented |
LE0450 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $1,023 | $1,625 | Not Implemented |
LE0450 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,186 | $2,470 | Not Implemented |
LE0450 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,643 | $36,750 | Not Implemented |
LE0345 # 10 Y:2012 | 10 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,720 | $7,500 | Not Implemented |
LE0345 # 11 Y:2012 | 11 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $53,742 | $3,200 | Implemented |
LE0345 # 01 Y:2012 | 01 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $737 | $2,800 | Not Implemented |
LE0345 # 09 Y:2012 | 09 | 2012 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $3,306 | $3,800 | Not Implemented |
LE0345 # 08 Y:2012 | 08 | 2012 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,858 | $12,810 | Not Implemented |
LE0345 # 07 Y:2012 | 07 | 2012 | REPLACE BOILER | $226,873 | $560,000 | Implemented |
LE0345 # 06 Y:2012 | 06 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $6,352 | $575 | Not Implemented |
LE0345 # 05 Y:2012 | 05 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $21,763 | $3,800 | Implemented |
LE0345 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,195 | $6,750 | Not Implemented |
LE0345 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,658 | $550 | Implemented |
LE0345 # 02 Y:2012 | 02 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $16,178 | $750 | Implemented |
LE0313 # 10 Y:2011 | 10 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,746 | $16,016 | Not Implemented |
LE0313 # 09 Y:2011 | 09 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $559 | $315 | Implemented |