Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
958
matching recommendationsNAICS | 313 | Textile Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0052 # 10 Y:2010 | 10 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,106 | $495 | Not Implemented |
DL0052 # 11 Y:2010 | 11 | 2010 | REDUCE VENTILATION AIR | $310 | $585 | Not Implemented |
GT0870 # 01 Y:2009 | 01 | 2009 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $625 | $0 | Implemented |
GT0870 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,570 | $1,000 | Not Implemented |
GT0870 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,245 | $20,050 | Implemented |
GT0870 # 04 Y:2009 | 04 | 2009 | INSTALL OCCUPANCY SENSORS | $5,810 | $620 | Implemented |
GT0870 # 05 Y:2009 | 05 | 2009 | USE SYNTHETIC LUBRICANT | $43,210 | $0 | Implemented |
GT0870 # 06 Y:2009 | 06 | 2009 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $1,500 | $6,399 | Implemented |
GT0870 # 07 Y:2009 | 07 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $33,910 | $45,000 | Implemented |
GT0870 # 08 Y:2009 | 08 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,796 | $7,656 | Not Implemented |
MA0653 # 01 Y:2009 | 01 | 2009 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $110,550 | $270,000 | Not Implemented |
MA0653 # 02 Y:2009 | 02 | 2009 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $37,210 | $68,000 | Not Implemented |
MA0653 # 03 Y:2009 | 03 | 2009 | REDUCE VENTILATION AIR | $16,188 | $752 | Implemented |
MA0653 # 04 Y:2009 | 04 | 2009 | CLOSE OFF UNNEEDED STEAM LINES | $3,551 | $500 | Not Implemented |
MA0653 # 05 Y:2009 | 05 | 2009 | INSULATE BARE EQUIPMENT | $2,840 | $7,510 | Implemented |
MA0653 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,375 | $6,125 | Not Implemented |
GT0867 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $52,318 | $89,971 | Not Implemented |
GT0867 # 02 Y:2009 | 02 | 2009 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $8,794 | $4,000 | Implemented |
GT0867 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,426 | $3,250 | Implemented |
GT0867 # 04 Y:2009 | 04 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,518 | $6,000 | Implemented |
GT0867 # 05 Y:2009 | 05 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,949 | $0 | Not Implemented |
GT0867 # 06 Y:2009 | 06 | 2009 | USE SYNTHETIC LUBRICANT | $1,440 | $0 | Implemented |
LE0291 # 01 Y:2009 | 01 | 2009 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $32,078 | $50,000 | Not Implemented |
LE0291 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $22,489 | $510 | Not Implemented |
LE0291 # 03 Y:2009 | 03 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,557 | $2,500 | Implemented |