Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
387
matching recommendationsNAICS | 3132 | Fabric Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0819 # 07 Y:2006 | 07 | 2006 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $298,817 | $375,000 | Not Implemented |
GT0819 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50,620 | $114,950 | Not Implemented |
GT0819 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $57,054 | $214,725 | Not Implemented |
GT0825 # 01 Y:2006 | 01 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,828 | $0 | Not Implemented |
GT0825 # 02 Y:2006 | 02 | 2006 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $95,828 | $140,000 | Not Implemented |
GT0825 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,150 | $4,150 | Not Implemented |
GT0825 # 04 Y:2006 | 04 | 2006 | INSTALL OCCUPANCY SENSORS | $13,107 | $1,500 | Not Implemented |
GT0825 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $78,754 | $182,180 | Not Implemented |
MI0126 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,617 | $16,000 | Implemented |
MI0126 # 02 Y:2006 | 02 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,323 | $1,020 | Implemented |
MI0126 # 03 Y:2006 | 03 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,331 | $212 | Implemented |
MI0126 # 04 Y:2006 | 04 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,497 | $1,750 | Implemented |
MI0126 # 05 Y:2006 | 05 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,474 | $0 | Implemented |
MI0126 # 06 Y:2006 | 06 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $42,242 | $140 | Implemented |
NC0325 # 01 Y:2005 | 01 | 2005 | INCREASE AMOUNT OF CONDENSATE RETURNED | $27,917 | $25,000 | Not Implemented |
NC0325 # 02 Y:2005 | 02 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $222,508 | $100,000 | Not Implemented |
NC0325 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,902 | $18,198 | Not Implemented |
NC0325 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $423 | $1,006 | Not Implemented |
NC0325 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,395 | $2,000 | Not Implemented |
NC0325 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,733 | $7,500 | Not Implemented |
OR0487 # 01 Y:2005 | 01 | 2005 | MINIMIZE WATER USAGE | $215,000 | $620,000 | Not Implemented |
OR0487 # 02 Y:2005 | 02 | 2005 | MINIMIZE WATER USAGE | $51,000 | $107,000 | Not Implemented |
OR0487 # 03 Y:2005 | 03 | 2005 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $39,000 | $16,400 | Not Implemented |
OR0487 # 04 Y:2005 | 04 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,600 | $23,000 | Not Implemented |
OR0487 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,630 | $0 | Implemented |