Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
214
matching recommendationsNAICS | 314110 | Carpet and Rug Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA3007 # 04 Y:2010 | 04 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $91,320 | $84,320 | Not Implemented |
UA3007 # 05 Y:2010 | 05 | 2010 | USE OPTIMUM THICKNESS INSULATION | $6,726 | $6,485 | Not Implemented |
UA0050 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $75,096 | $640 | Not Implemented |
UA0050 # 02 Y:2010 | 02 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $123,482 | $302,000 | Implemented |
UA0050 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $42,529 | $45,740 | Implemented |
UA0050 # 04 Y:2010 | 04 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $103,313 | $74,525 | Not Implemented |
UA0050 # 05 Y:2010 | 05 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,904 | $2,890 | Implemented |
UA0050 # 06 Y:2010 | 06 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $70,430 | $4,075 | Not Implemented |
UA0050 # 07 Y:2010 | 07 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,300 | $160 | Implemented |
GT0846 # 01 Y:2008 | 01 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $61,777 | $40,000 | Implemented |
GT0846 # 02 Y:2008 | 02 | 2008 | USE MINIMUM STEAM OPERATING PRESSURE | $16,146 | $15,536 | Implemented |
GT0846 # 03 Y:2008 | 03 | 2008 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $830 | $1,094 | Not Implemented |
GT0846 # 04 Y:2008 | 04 | 2008 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $17,989 | $26,900 | Not Implemented |
GT0846 # 05 Y:2008 | 05 | 2008 | HEAT WATER WITH EXHAUST HEAT | $551,313 | $130,000 | Not Implemented |
GT0846 # 06 Y:2008 | 06 | 2008 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $59,040 | $65,000 | Implemented |
GT0846 # 07 Y:2008 | 07 | 2008 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $155,720 | $30,000 | Implemented |
GT0846 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,504 | $70,103 | Implemented |
GT0846 # 09 Y:2008 | 09 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $18,206 | $35,000 | Not Implemented |
GT0838 # 01 Y:2007 | 01 | 2007 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $25,825 | $10,000 | Not Implemented |
GT0838 # 02 Y:2007 | 02 | 2007 | USE MINIMUM SAFE OVEN VENTILATION | $5,955 | $6,000 | Not Implemented |
GT0838 # 03 Y:2007 | 03 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,976 | $0 | Not Implemented |
GT0838 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,908 | $0 | Not Implemented |
GT0838 # 05 Y:2007 | 05 | 2007 | USE MINIMUM STEAM OPERATING PRESSURE | $17,020 | $0 | Not Implemented |
GT0838 # 06 Y:2007 | 06 | 2007 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,288 | $3,975 | Not Implemented |
GT0838 # 07 Y:2007 | 07 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,338 | $2,250 | Not Implemented |