Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

58

matching recommendations
Reset
NAICS 315220 Men’s and Boys’ Cut and Sew Apparel Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1510 # 04 Y:2015 04 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,187 $2,890 Implemented
UK1510 # 12 Y:2015 12 2015 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $310 $90 Implemented
UK1510 # 11 Y:2015 11 2015 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $427 $273 Implemented
UK1510 # 10 Y:2015 10 2015 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $305 $886 Not Implemented
UK1510 # 09 Y:2015 09 2015 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $445 $650 Not Implemented
UK1510 # 07 Y:2015 07 2015 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $849 $0 Not Implemented
UK1510 # 06 Y:2015 06 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $1,236 $0 Implemented
UK1510 # 05 Y:2015 05 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,527 $2,143 Implemented
UK1510 # 08 Y:2015 08 2015 USE ONLY CERTIFIED MOTOR REPAIR SHOPS $623 $2,031 Not Implemented
UK1510 # 03 Y:2015 03 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,580 $2,360 Implemented
UK1510 # 02 Y:2015 02 2015 USE PHOTOCELL CONTROLS $3,354 $750 Implemented
UK1510 # 01 Y:2015 01 2015 UPGRADE CONTROLS ON COMPRESSORS $10,047 $6,250 Not Implemented
DL0033 # 02 Y:2009 02 2009 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $5,409 $9,300 Implemented
DL0033 # 03 Y:2009 03 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,789 $16,100 Implemented
DL0033 # 04 Y:2009 04 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,737 $10,000 Implemented
DL0033 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $580 $80 Implemented
DL0033 # 06 Y:2009 06 2009 UPGRADE CONTROLS ON COMPRESSORS $3,596 $12,500 Not Implemented
DL0033 # 07 Y:2009 07 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $310 $150 Implemented
DL0033 # 08 Y:2009 08 2009 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $6,433 $26,980 Implemented
DL0033 # 01 Y:2009 01 2009 USE MINIMUM STEAM OPERATING PRESSURE $1,091 $0 Implemented
NC0381 # 01 Y:2008 01 2008 RECOVER WASTE HEAT FROM EQUIPMENT $80,420 $183,000 Not Implemented
NC0381 # 03 Y:2008 03 2008 ADJUST BURNERS FOR EFFICIENT OPERATION $1,430 $800 Implemented
NC0381 # 04 Y:2008 04 2008 INSULATE BARE EQUIPMENT $1,224 $1,030 Implemented
NC0381 # 05 Y:2008 05 2008 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $998 $500 Implemented
NC0381 # 06 Y:2008 06 2008 RECOVER WASTE HEAT FROM EQUIPMENT $6,183 $4,900 Not Implemented