Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
896
matching recommendationsNAICS | 32111 | Sawmills and Wood Preservation |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0246 # 03 Y:2006 | 03 | 2006 | USE PHOTOCELL CONTROLS | $882 | $120 | Implemented |
LL0246 # 04 Y:2006 | 04 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $838 | $30 | Implemented |
LL0246 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $456 | $280 | Implemented |
LL0246 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $139 | $105 | Not Implemented |
LL0246 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $49 | $120 | Not Implemented |
WV0333 # 01 Y:2006 | 01 | 2006 | BURN WASTE OIL FOR HEAT | $23,934 | $19,500 | Not Implemented |
WV0333 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,663 | $195 | Implemented |
WV0333 # 03 Y:2006 | 03 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $2,692 | $544 | Implemented |
WV0333 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,819 | $800 | Implemented |
WV0333 # 05 Y:2006 | 05 | 2006 | INSTALL OCCUPANCY SENSORS | $397 | $210 | Not Implemented |
WV0333 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $460 | $0 | Not Implemented |
OR0497 # 01 Y:2006 | 01 | 2006 | OPTIMIZE PLANT POWER FACTOR | $6,400 | $3,500 | Not Implemented |
OR0497 # 02 Y:2006 | 02 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $4,200 | $1,800 | Not Implemented |
OR0497 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,550 | $2,550 | Implemented |
OR0497 # 04 Y:2006 | 04 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,700 | $39,000 | Implemented |
OR0495 # 14 Y:2006 | 14 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,900 | $31,000 | Not Implemented |
OR0495 # 15 Y:2006 | 15 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,500 | $15,000 | Not Implemented |
OR0495 # 01 Y:2006 | 01 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $249,000 | $15,000 | Not Implemented |
OR0495 # 02 Y:2006 | 02 | 2006 | $379,000 | $168,000 | Not Implemented | |
OR0495 # 03 Y:2006 | 03 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $15,400 | $6,000 | Not Implemented |
OR0495 # 04 Y:2006 | 04 | 2006 | OPTIMIZE PLANT POWER FACTOR | $15,000 | $8,750 | Implemented |
OR0495 # 05 Y:2006 | 05 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $8,900 | $900 | Implemented |
OR0495 # 06 Y:2006 | 06 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,800 | $1,500 | Not Implemented |
OR0495 # 07 Y:2006 | 07 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $3,900 | $1,800 | Implemented |
OR0495 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,400 | $2,100 | Not Implemented |