Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
188
matching recommendationsNAICS | 321114 | Wood Preservation |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0132 # 07 Y:2014 | 07 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,339 | $50 | Implemented |
UA0132 # 06 Y:2014 | 06 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,554 | $6,336 | Not Implemented |
UA0132 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $875 | $1,522 | Implemented |
UA0128 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,565 | $6,495 | Implemented |
UA0128 # 01 Y:2014 | 01 | 2014 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $125,709 | $180,000 | Not Implemented |
UA0128 # 02 Y:2014 | 02 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $24,552 | $12,050 | Not Implemented |
UA0128 # 04 Y:2014 | 04 | 2014 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $11,022 | $7,500 | Not Implemented |
UA0128 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,158 | $7,334 | Not Implemented |
UA0128 # 08 Y:2014 | 08 | 2014 | USE PHOTOCELL CONTROLS | $605 | $1,725 | Implemented |
UA0128 # 03 Y:2014 | 03 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,032 | $35,000 | Not Implemented |
UA0128 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,193 | $6,764 | Not Implemented |
TT0111 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,000 | $5,000 | Implemented |
TT0111 # 01 Y:2013 | 01 | 2013 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $6,000 | $5,000 | Not Implemented |
TT0111 # 04 Y:2013 | 04 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,000 | $4,000 | Implemented |
TT0111 # 05 Y:2013 | 05 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,000 | $1,500 | Implemented |
TT0111 # 02 Y:2013 | 02 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,000 | $50,000 | Not Implemented |
NC0480 # 06 Y:2013 | 06 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $6,224 | $13,210 | Implemented |
NC0480 # 04 Y:2013 | 04 | 2013 | USE PHOTOCELL CONTROLS | $1,282 | $1,250 | Implemented |
NC0480 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,008 | $4,271 | Implemented |
NC0480 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,460 | $100 | Implemented |
NC0480 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $481 | $1,490 | Implemented |
NC0480 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $297 | $264 | Implemented |
NC0480 # 07 Y:2013 | 07 | 2013 | USE PHOTOCELL CONTROLS | $4,207 | $15,472 | Not Implemented |
TT0096 # 02 Y:2012 | 02 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,193 | $1,753 | Not Implemented |
TT0096 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $463 | $0 | Implemented |