Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
188
matching recommendationsNAICS | 321114 | Wood Preservation |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0572 # 06 Y:2011 | 06 | 2011 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $8,030 | $14,750 | Not Implemented |
OR0572 # 07 Y:2011 | 07 | 2011 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,280 | $500 | Implemented |
OR0572 # 08 Y:2011 | 08 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,310 | $1,170 | Not Implemented |
MS0345 # 01 Y:2009 | 01 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,308 | $7,084 | Not Implemented |
MS0345 # 02 Y:2009 | 02 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $13,965 | $187 | Implemented |
MS0345 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,762 | $10,935 | Not Implemented |
MS0345 # 04 Y:2009 | 04 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,977 | $4,445 | Implemented |
MS0345 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,379 | $462 | Implemented |
MS0345 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,924 | $12,190 | Not Implemented |
MS0345 # 07 Y:2009 | 07 | 2009 | USE PHOTOCELL CONTROLS | $1,095 | $630 | Not Implemented |
MS0345 # 08 Y:2009 | 08 | 2009 | INSTALL OCCUPANCY SENSORS | $948 | $864 | Implemented |
MS0345 # 09 Y:2009 | 09 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $330 | $168 | Implemented |
MS0343 # 01 Y:2009 | 01 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,084 | $4,017 | Implemented |
MS0343 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,954 | $401 | Implemented |
MS0343 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,621 | $6,350 | Not Implemented |
MS0343 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,176 | $4,546 | Not Implemented |
MS0343 # 05 Y:2009 | 05 | 2009 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $161 | $14 | Implemented |
AS0424 # 01 Y:2006 | 01 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $6,478 | $800 | n/a |
AS0424 # 02 Y:2006 | 02 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,125 | $44,393 | n/a |
AS0424 # 03 Y:2006 | 03 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,418 | $1,000 | n/a |
AS0424 # 04 Y:2006 | 04 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,909 | $2,240 | n/a |
LL0238 # 01 Y:2005 | 01 | 2005 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $60,523 | $0 | Not Implemented |
LL0238 # 02 Y:2005 | 02 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $47,162 | $3,000 | Implemented |
LL0238 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,179 | $1,500 | Implemented |
LL0238 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $2,207 | $500 | Implemented |