Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

654

matching recommendations
Reset
NAICS 32121 Veneer, Plywood, and Engineered Wood Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0427 # 02 Y:2011 02 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $209,278 $1,200 Not Implemented
NC0427 # 03 Y:2011 03 2011 KEEP BOILER TUBES CLEAN $164,666 $20,000 Implemented
NC0427 # 04 Y:2011 04 2011 KEEP BOILER TUBES CLEAN $104,205 $18,000 Implemented
NC0427 # 05 Y:2011 05 2011 LOWER OPERATING PRESSURE OF CONDENSER (STEAM) $178,345 $50,000 Implemented
NC0427 # 06 Y:2011 06 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $10,000 $200 Implemented
NC0427 # 07 Y:2011 07 2011 INSULATE FEEDWATER TANK $3,200 $1,200 Implemented
NC0427 # 08 Y:2011 08 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $3,000 $600 Implemented
NC0427 # 09 Y:2011 09 2011 REPAIR AND ELIMINATE STEAM LEAKS $106,205 $1,200 Implemented
NC0427 # 10 Y:2011 10 2011 REPAIR OR REPLACE STEAM TRAPS $5,500 $150 Not Implemented
NC0427 # 11 Y:2011 11 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $1,050 Not Implemented
NC0427 # 12 Y:2011 12 2011 INCREASE AMOUNT OF CONDENSATE RETURNED $126,880 $500,000 Not Implemented
MS0370 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $52,080 $43,618 Not Implemented
MS0370 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $21,993 $263 Not Implemented
MS0370 # 03 Y:2011 03 2011 REPAIR AND ELIMINATE STEAM LEAKS $534 $312 Not Implemented
OR0567 # 01 Y:2011 01 2011 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS $2,000 $1,510 Implemented
OR0567 # 02 Y:2011 02 2011 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $8,491 $8,300 Not Implemented
OR0567 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $878 $737 Not Implemented
OR0567 # 04 Y:2011 04 2011 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,800 $6,700 Not Implemented
OR0567 # 05 Y:2011 05 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $12,000 $5,580 Implemented
OR0567 # 06 Y:2011 06 2011 INSULATE BARE EQUIPMENT $1,248 $2,547 Implemented
OR0567 # 07 Y:2011 07 2011 ELIMINATE/REDUCE AN OPERATION $17,603 $2,480 Not Implemented
MS0359 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $67,464 $34,894 Not Implemented
MS0359 # 02 Y:2010 02 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $9,253 $1,635 Implemented
MS0359 # 03 Y:2010 03 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,778 $241 Implemented
MS0359 # 04 Y:2010 04 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $2,850 $2,432 Not Implemented