Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

54

matching recommendations
Reset
NAICS 32121 Veneer, Plywood, and Engineered Wood Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0512 # 11 Y:2014 11 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $440 $560 Not Implemented
NC0512 # 10 Y:2014 10 2014 INSTALL OCCUPANCY SENSORS $642 $944 Not Implemented
NC0512 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $375 $1,605 Not Implemented
NC0512 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,636 $43,944 Not Implemented
NC0463 # 01 Y:2012 01 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $15,737 $15,000 Not Implemented
NC0463 # 02 Y:2012 02 2012 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,159 $1,400 Implemented
NC0463 # 03 Y:2012 03 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,208 $200 Implemented
NC0463 # 04 Y:2012 04 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,015 $1,124 Implemented
NC0463 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24 $135 Not Implemented
NC0463 # 06 Y:2012 06 2012 RECOVER WASTE HEAT FROM EQUIPMENT $4,367 $5,000 Implemented
NC0427 # 06 Y:2011 06 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $10,000 $200 Implemented
NC0427 # 12 Y:2011 12 2011 INCREASE AMOUNT OF CONDENSATE RETURNED $126,880 $500,000 Not Implemented
NC0427 # 11 Y:2011 11 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $1,050 Not Implemented
NC0427 # 10 Y:2011 10 2011 REPAIR OR REPLACE STEAM TRAPS $5,500 $150 Not Implemented
NC0427 # 09 Y:2011 09 2011 REPAIR AND ELIMINATE STEAM LEAKS $106,205 $1,200 Implemented
NC0427 # 08 Y:2011 08 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $3,000 $600 Implemented
NC0427 # 07 Y:2011 07 2011 INSULATE FEEDWATER TANK $3,200 $1,200 Implemented
NC0427 # 05 Y:2011 05 2011 LOWER OPERATING PRESSURE OF CONDENSER (STEAM) $178,345 $50,000 Implemented
NC0427 # 04 Y:2011 04 2011 KEEP BOILER TUBES CLEAN $104,205 $18,000 Implemented
NC0427 # 03 Y:2011 03 2011 KEEP BOILER TUBES CLEAN $164,666 $20,000 Implemented
NC0427 # 02 Y:2011 02 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $209,278 $1,200 Not Implemented
NC0427 # 01 Y:2011 01 2011 BURN A LESS EXPENSIVE GRADE OF FUEL $155,882 $10,000 Implemented
NC0416 # 04 Y:2010 04 2010 RECOVER WASTE HEAT FROM EQUIPMENT $11,462 $6,800 Not Implemented
NC0416 # 02 Y:2010 02 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $14,117 $50 Implemented
NC0416 # 01 Y:2010 01 2010 KEEP BOILER TUBES CLEAN $359,066 $411,700 Not Implemented