Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,548
matching recommendationsNAICS | 3219 | Other Wood Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0314 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,017 | $39,066 | Not Implemented |
OR0566 # 01 Y:2011 | 01 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,230 | $635 | Implemented |
OR0566 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $4,340 | $9,990 | Implemented |
OR0566 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,690 | $1,690 | Implemented |
OR0566 # 04 Y:2011 | 04 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $8,620 | $37,500 | Not Implemented |
OR0566 # 05 Y:2011 | 05 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $15,200 | $146,000 | Not Implemented |
LL0339 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $271,505 | $2,920 | Implemented |
LL0339 # 02 Y:2010 | 02 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $204,298 | $966,460 | Implemented |
LL0339 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $152,895 | $42,400 | Implemented |
LL0339 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $31,760 | $6,240 | Not Implemented |
LL0339 # 05 Y:2010 | 05 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,510 | $10,605 | Not Implemented |
LL0339 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,365 | $1,950 | Not Implemented |
LL0339 # 07 Y:2010 | 07 | 2010 | INSTALL OCCUPANCY SENSORS | $3,388 | $1,950 | Not Implemented |
LL0339 # 08 Y:2010 | 08 | 2010 | USE PHOTOCELL CONTROLS | $1,302 | $150 | Not Implemented |
LL0339 # 09 Y:2010 | 09 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $457 | $623 | Not Implemented |
OR0562 # 01 Y:2010 | 01 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $8,447 | $2,500 | Implemented |
OR0562 # 02 Y:2010 | 02 | 2010 | BURN A LESS EXPENSIVE GRADE OF FUEL | $6,592 | $14,997 | Not Implemented |
OR0562 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,447 | $2,724 | Implemented |
OR0562 # 04 Y:2010 | 04 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,192 | $0 | Implemented |
NC0408 # 01 Y:2010 | 01 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,189 | $1,000 | Implemented |
NC0408 # 02 Y:2010 | 02 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,644 | $1,689 | Implemented |
NC0408 # 03 Y:2010 | 03 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $5,428 | $5,500 | Implemented |
NC0408 # 04 Y:2010 | 04 | 2010 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $712,007 | $1,750,000 | Implemented |
NC0408 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,000 | $7,665 | Implemented |
NC0408 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $27,873 | $53,873 | Implemented |