Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

957

matching recommendations
Reset
NAICS 32191 Millwork
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0215 # 04 Y:2019 04 2019 OPTIMIZE PLANT POWER FACTOR $14,409 $72,000 Not Implemented
TT0215 # 05 Y:2019 05 2019 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,811 $5,500 Not Implemented
TT0215 # 06 Y:2019 06 2019 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $9,181 $40,600 Not Implemented
TT0215 # 07 Y:2019 07 2019 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,783 $15,000 Not Implemented
TT0215 # 08 Y:2019 08 2019 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,173 $6,450 Not Implemented
TT0215 # 09 Y:2019 09 2019 INSULATE BARE EQUIPMENT $2,400 $4,140 Not Implemented
SU0453 # 01 Y:2018 01 2018 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,533 $0 Not Implemented
SU0453 # 02 Y:2018 02 2018 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $773 $0 Not Implemented
SU0453 # 03 Y:2018 03 2018 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $548 $0 Not Implemented
SU0453 # 04 Y:2018 04 2018 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,502 $451 Implemented
SU0453 # 05 Y:2018 05 2018 ELIMINATE/REDUCE AN OPERATION $1,542 $463 Implemented
SU0453 # 06 Y:2018 06 2018 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $3,220 $1,619 Implemented
SU0453 # 07 Y:2018 07 2018 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $325 $239 Implemented
SU0453 # 08 Y:2018 08 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $266 $258 Implemented
SU0453 # 09 Y:2018 09 2018 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $119 $169 Not Implemented
SU0453 # 10 Y:2018 10 2018 USE PHOTOCELL CONTROLS $248 $403 Implemented
SU0453 # 11 Y:2018 11 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $212 $364 Implemented
NL0010 # 01 Y:2017 01 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $52,500 $106,600 Implemented
NL0010 # 02 Y:2017 02 2017 INSTALL OCCUPANCY SENSORS $3,700 $2,470 Not Implemented
NL0010 # 03 Y:2017 03 2017 MAINTAIN MACHINES TO REDUCE LEAKS $700 $520 Implemented
UK1706 # 01 Y:2017 01 2017 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $137 $100 Implemented
UK1706 # 02 Y:2017 02 2017 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $7,994 $2,000 Implemented
UK1706 # 03 Y:2017 03 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $4,191 $0 Not Implemented
UK1706 # 04 Y:2017 04 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $1,753 $1,000 Implemented
UK1706 # 05 Y:2017 05 2017 USE OPTIMUM TEMPERATURE $344 $0 Not Implemented