Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
294
matching recommendationsNAICS | 321999 | All Other Miscellaneous Wood Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0699 # 01 Y:2018 | 01 | 2018 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $4,167 | $1,495 | Implemented |
OR0699 # 02 Y:2018 | 02 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,077 | $2,087 | Not Implemented |
OR0699 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,314 | $3,982 | Implemented |
OR0699 # 04 Y:2018 | 04 | 2018 | UPGRADE CONTROLS ON COMPRESSORS | $6,151 | $23,153 | Implemented |
OR0699 # 05 Y:2018 | 05 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $592 | $10,650 | Not Implemented |
WV0557 # 09 Y:2018 | 09 | 2018 | MINIMIZE WATER USAGE | $2,486 | $5,600 | Not Implemented |
WV0557 # 12 Y:2018 | 12 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $508 | $2,480 | Implemented |
WV0557 # 01 Y:2018 | 01 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $65,760 | $117,200 | Implemented |
WV0557 # 02 Y:2018 | 02 | 2018 | REPAIR AND ELIMINATE STEAM LEAKS | $43,281 | $33,600 | Implemented |
WV0557 # 03 Y:2018 | 03 | 2018 | ADD AREA LIGHTING SWITCHES | $22,313 | $25,000 | Not Implemented |
WV0557 # 10 Y:2018 | 10 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,424 | $90 | Not Implemented |
WV0557 # 08 Y:2018 | 08 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,390 | $1,950 | Not Implemented |
WV0557 # 07 Y:2018 | 07 | 2018 | INSULATE BARE EQUIPMENT | $3,480 | $16,000 | Not Implemented |
WV0557 # 06 Y:2018 | 06 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,808 | $0 | Not Implemented |
WV0557 # 05 Y:2018 | 05 | 2018 | UPGRADE CONTROLS ON COMPRESSORS | $14,479 | $27,450 | Implemented |
WV0557 # 04 Y:2018 | 04 | 2018 | DEVELOP A REPAIR/REPLACE POLICY | $13,930 | $2,320 | Implemented |
WV0557 # 11 Y:2018 | 11 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,022 | $1,365 | Not Implemented |
BS0089 # 07 Y:2016 | 07 | 2016 | OPTIMIZE PLANT POWER FACTOR | $15,910 | $115,903 | Not Implemented |
BS0089 # 02 Y:2016 | 02 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $7,566 | $6,400 | Not Implemented |
BS0089 # 03 Y:2016 | 03 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,855 | $654 | Not Implemented |
BS0089 # 04 Y:2016 | 04 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,615 | $4,480 | Not Implemented |
BS0089 # 05 Y:2016 | 05 | 2016 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,760 | $4,580 | Not Implemented |
BS0089 # 06 Y:2016 | 06 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,303 | $1,200 | Not Implemented |
BS0089 # 08 Y:2016 | 08 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,610 | $15,011 | Not Implemented |
BS0089 # 01 Y:2016 | 01 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,075 | $353 | Not Implemented |