Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
89
matching recommendationsNAICS | 322 | Paper Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0894 # 07 Y:2013 | 07 | 2013 | INSULATE BARE EQUIPMENT | $142 | $350 | Implemented |
UD0894 # 08 Y:2013 | 08 | 2013 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $12,240 | $30,550 | Not Implemented |
UD0894 # 09 Y:2013 | 09 | 2013 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $10,400 | $40,600 | Not Implemented |
WV0464 # 02 Y:2013 | 02 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $17,893 | $1,000 | Not Implemented |
WV0464 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,493 | $17,640 | Implemented |
WV0464 # 04 Y:2013 | 04 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,702 | $0 | Implemented |
WV0464 # 07 Y:2013 | 07 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $1,256 | $1,068 | Implemented |
WV0464 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,550 | $32 | Implemented |
WV0464 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $4,654 | $984 | Implemented |
WV0464 # 01 Y:2013 | 01 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $38,155 | $6,768 | Not Implemented |
WV0464 # 11 Y:2013 | 11 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $323 | $500 | Implemented |
WV0464 # 09 Y:2013 | 09 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $935 | $3,500 | Not Implemented |
WV0464 # 08 Y:2013 | 08 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $987 | $2,640 | Not Implemented |
WV0464 # 10 Y:2013 | 10 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $791 | $1,320 | Not Implemented |
UD0804 # 02 Y:2009 | 02 | 2009 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $38,869 | $12,000 | Implemented |
UD0804 # 12 Y:2009 | 12 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,004 | $12,597 | Not Implemented |
UD0804 # 03 Y:2009 | 03 | 2009 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $35,001 | $9,000 | Implemented |
UD0804 # 04 Y:2009 | 04 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $23,089 | $4,000 | Implemented |
UD0804 # 05 Y:2009 | 05 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,277 | $500 | Implemented |
UD0804 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,589 | $5,523 | Not Implemented |
UD0804 # 10 Y:2009 | 10 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,963 | $2,000 | Not Implemented |
UD0804 # 11 Y:2009 | 11 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,128 | $0 | Implemented |
UD0804 # 16 Y:2009 | 16 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,160 | $2,094 | Not Implemented |
UD0804 # 15 Y:2009 | 15 | 2009 | ISOLATE HOT OR COLD EQUIPMENT | $1,306 | $0 | Implemented |
UD0804 # 14 Y:2009 | 14 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,920 | $1,000 | Not Implemented |