Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
107
matching recommendationsNAICS | 32221 | Paperboard Container Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0301 # 03 Y:2004 | 03 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $9,891 | $17,930 | Not Implemented |
NC0301 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $812 | $100 | Not Implemented |
NC0301 # 02 Y:2004 | 02 | 2004 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $32,270 | $2,500 | Not Implemented |
NC0301 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,961 | $3,154 | Not Implemented |
NC0301 # 01 Y:2004 | 01 | 2004 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $39,250 | $10,000 | Not Implemented |
NC0301 # 04 Y:2004 | 04 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $17,538 | $27,880 | Not Implemented |
MS0261 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,530 | $1,992 | Not Implemented |
MS0261 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,624 | $25,372 | Not Implemented |
MS0261 # 02 Y:2004 | 02 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,290 | $15,000 | Not Implemented |
MS0261 # 09 Y:2004 | 09 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $881 | $66 | Not Implemented |
MS0261 # 07 Y:2004 | 07 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $1,491 | $19 | Not Implemented |
MS0261 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,148 | $3,031 | Not Implemented |
MS0261 # 06 Y:2004 | 06 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,883 | $0 | Not Implemented |
MS0261 # 03 Y:2004 | 03 | 2004 | USE RADIANT HEATER FOR SPOT HEATING | $6,881 | $3,275 | Not Implemented |
MS0261 # 04 Y:2004 | 04 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,978 | $2,968 | Not Implemented |
LE0195 # 09 Y:2004 | 09 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,529 | $12,960 | Not Implemented |
LE0195 # 11 Y:2004 | 11 | 2004 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $960 | $200 | Implemented |
LE0195 # 10 Y:2004 | 10 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,299 | $1,200 | Implemented |
LE0195 # 08 Y:2004 | 08 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,089 | $0 | Implemented |
LE0195 # 07 Y:2004 | 07 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,095 | $0 | Implemented |
LE0195 # 01 Y:2004 | 01 | 2004 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $575,674 | $984,000 | Not Implemented |
LE0195 # 02 Y:2004 | 02 | 2004 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $29,156 | $14,088 | Not Implemented |
LE0195 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $33,048 | $40,000 | Not Implemented |
LE0195 # 04 Y:2004 | 04 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $19,946 | $48,000 | Implemented |
LE0195 # 05 Y:2004 | 05 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,168 | $6,683 | Implemented |