Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
140
matching recommendationsNAICS | 32221 | Paperboard Container Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0108 # 01 Y:2005 | 01 | 2005 | OPTIMIZE PLANT POWER FACTOR | $11,100 | $22,000 | Not Implemented |
TA0108 # 02 Y:2005 | 02 | 2005 | INSULATE BARE EQUIPMENT | $2,910 | $495 | Implemented |
TA0108 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,647 | $120 | Implemented |
TA0108 # 04 Y:2005 | 04 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,590 | $0 | Implemented |
TA0108 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,530 | $11,050 | Implemented |
TA0108 # 05 Y:2005 | 05 | 2005 | USE MINIMUM SAFE OVEN VENTILATION | $300 | $0 | Not Implemented |
UM0290 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,296 | $1,950 | Implemented |
UM0290 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,268 | $11,077 | Implemented |
UM0290 # 05 Y:2005 | 05 | 2005 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,242 | $0 | Not Implemented |
UM0290 # 07 Y:2005 | 07 | 2005 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $365 | $720 | Implemented |
UM0290 # 03 Y:2005 | 03 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,868 | $2,650 | Implemented |
UM0290 # 04 Y:2005 | 04 | 2005 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $2,753 | $6,230 | Implemented |
UM0290 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $7,943 | $12,500 | Not Implemented |
AS0409 # 05 Y:2005 | 05 | 2005 | USE PHOTOCELL CONTROLS | $1,730 | $4,650 | Not Implemented |
AS0409 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,097 | $10,861 | Not Implemented |
AS0409 # 07 Y:2005 | 07 | 2005 | USE SOLAR HEAT TO HEAT WATER | $1,555 | $12,000 | Not Implemented |
AS0409 # 06 Y:2005 | 06 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,337 | $1,000 | Not Implemented |
AS0409 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,404 | $11,000 | Not Implemented |
AS0409 # 02 Y:2005 | 02 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $13,305 | $10,000 | Not Implemented |
AS0409 # 03 Y:2005 | 03 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,055 | $8,000 | Not Implemented |
NC0322 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $462 | $100 | Implemented |
NC0322 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $723 | $298 | Implemented |
NC0322 # 03 Y:2005 | 03 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $74,009 | $100,000 | Not Implemented |
NC0322 # 02 Y:2005 | 02 | 2005 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $8,353 | $2,650 | Implemented |
NC0322 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $217 | $2,000 | Implemented |