Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

411

matching recommendations
Reset
NAICS 322211 Corrugated and Solid Fiber Box Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0383 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,059 $2,380 Implemented
IA0383 # 08 Y:2006 08 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,920 $1,786 Implemented
IA0382 # 01 Y:2006 01 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,256 $391 Implemented
IA0382 # 03 Y:2006 03 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,778 $264 Implemented
IA0382 # 04 Y:2006 04 2006 RECOVER WASTE HEAT FROM EQUIPMENT $4,991 $501 Implemented
IA0382 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,869 $51,870 Implemented
IA0382 # 09 Y:2006 09 2006 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $669 $645 Implemented
IA0382 # 13 Y:2006 13 2006 REPAIR AND ELIMINATE STEAM LEAKS $1,292 $600 Implemented
IA0382 # 14 Y:2006 14 2006 DIRECT WARMEST AIR TO COMBUSTION INTAKE $19,064 $1,000 Implemented
IA0382 # 15 Y:2006 15 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $56,152 $18,000 Implemented
IA0382 # 17 Y:2006 17 2006 RECOVER WASTE HEAT FROM EQUIPMENT $44,129 $95,000 Implemented
IA0382 # 19 Y:2006 19 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,614 $1,590 Implemented
IA0382 # 20 Y:2006 20 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $268 $303 Implemented
IA0382 # 21 Y:2006 21 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $5,293 $1,000 Implemented
IA0381 # 01 Y:2006 01 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,587 $500 Implemented
IA0381 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $593 $877 Implemented
IA0381 # 05 Y:2006 05 2006 INSTALL OCCUPANCY SENSORS $1,196 $300 Implemented
IA0381 # 07 Y:2006 07 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,382 $458 Implemented
IA0381 # 10 Y:2006 10 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $20,975 $250 Implemented
IA0381 # 16 Y:2006 16 2006 ADJUST BURNERS FOR EFFICIENT OPERATION $6,473 $1,000 Implemented
IA0381 # 19 Y:2006 19 2006 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $366 $50 Implemented
IA0381 # 20 Y:2006 20 2006 REPAIR AND ELIMINATE STEAM LEAKS $252 $600 Implemented
IA0381 # 21 Y:2006 21 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $4,144 $1,925 Implemented
GT0816 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $15,818 $4,500 Implemented
GT0816 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,196 $1,422 Implemented