Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,910

matching recommendations
Reset
NAICS 3231 Printing and Related Support Activities
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0392 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $464 $223 Implemented
SU0392 # 08 Y:2015 08 2015 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $251 $654 Implemented
SU0392 # 09 Y:2015 09 2015 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $108 $281 Implemented
SU0392 # 10 Y:2015 10 2015 REDUCE VENTILATION AIR $234 $794 Implemented
SU0392 # 11 Y:2015 11 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,745 $8,154 Implemented
DL0148 # 01 Y:2015 01 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $19,390 $0 Implemented
DL0148 # 02 Y:2015 02 2015 REDUCE VENTILATION AIR $11,465 $0 Not Implemented
DL0148 # 03 Y:2015 03 2015 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $178,010 $40,300 Implemented
DL0148 # 04 Y:2015 04 2015 REDUCE VENTILATION AIR $7,060 $5,680 Not Implemented
DL0148 # 05 Y:2015 05 2015 RECOVER WASTE HEAT FROM EQUIPMENT $11,110 $21,440 Not Implemented
DL0148 # 06 Y:2015 06 2015 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $154,200 $348,840 Not Implemented
DL0148 # 07 Y:2015 07 2015 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $13,630 $31,200 Not Implemented
DL0148 # 08 Y:2015 08 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $26,240 $75,600 Not Implemented
DL0148 # 09 Y:2015 09 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $678,100 $3,234,220 Implemented
DL0148 # 10 Y:2015 10 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $38,020 $217,230 Implemented
OK0920 # 01 Y:2015 01 2015 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $11,299 $3,815 Not Implemented
OK0920 # 02 Y:2015 02 2015 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $2,194 $0 Not Implemented
OK0920 # 03 Y:2015 03 2015 INSTALL SET-BACK TIMERS $2,270 $1,550 Not Implemented
OK0920 # 04 Y:2015 04 2015 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $820 $3,450 Not Implemented
OK0920 # 05 Y:2015 05 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,796 $15,971 Not Implemented
OK0920 # 06 Y:2015 06 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,190 $5,218 Not Implemented
OK0920 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,921 $2,360 Not Implemented
OK0920 # 08 Y:2015 08 2015 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $1,051 $0 Not Implemented
OK0920 # 09 Y:2015 09 2015 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $15,138 $18,243 Not Implemented
OK0920 # 10 Y:2015 10 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,980 $1,500 Not Implemented