Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
372
matching recommendationsNAICS | 324 | Petroleum and Coal Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0468 # 09 Y:2011 | 09 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $4,944 | $2,436 | Implemented |
IA0468 # 10 Y:2011 | 10 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,265 | $1,000 | Implemented |
UA3008 # 02 Y:2010 | 02 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $5,598 | $17,500 | Implemented |
UA3008 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $6,109 | $337 | Implemented |
UA3008 # 03 Y:2010 | 03 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,470 | $2,149 | Implemented |
CO0637 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,860 | $24,000 | Implemented |
CO0637 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,200 | $460 | Implemented |
CO0637 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,650 | $20,950 | Implemented |
DL0056 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM TEMPERATURE | $7,644 | $100 | Implemented |
DL0056 # 05 Y:2010 | 05 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,000 | $300 | Implemented |
DL0056 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $184,560 | $1,200,000 | Implemented |
SF0387 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $747 | $0 | Implemented |
SF0387 # 03 Y:2010 | 03 | 2010 | USE PHOTOCELL CONTROLS | $7,756 | $1,353 | Implemented |
SF0387 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,874 | $1,627 | Implemented |
SF0387 # 05 Y:2010 | 05 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,964 | $7,727 | Implemented |
SF0387 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM THICKNESS INSULATION | $791 | $1,536 | Implemented |
SF0387 # 07 Y:2010 | 07 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $397 | $798 | Implemented |
SF0387 # 08 Y:2010 | 08 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,393 | $2,851 | Implemented |
SF0387 # 09 Y:2010 | 09 | 2010 | INSTALL OCCUPANCY SENSORS | $920 | $2,132 | Implemented |
SF0387 # 10 Y:2010 | 10 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,160 | $3,840 | Implemented |
SF0387 # 11 Y:2010 | 11 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,342 | $6,259 | Implemented |
DL0045 # 09 Y:2010 | 09 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $20,229 | $100,000 | Implemented |
DL0045 # 06 Y:2010 | 06 | 2010 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $3,560 | $2,000 | Implemented |
DL0045 # 02 Y:2010 | 02 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,204 | $0 | Implemented |
CO0631 # 01 Y:2010 | 01 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,000 | $19,665 | Implemented |