Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsNAICS | 324 | Petroleum and Coal Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0247 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,108 | $80 | Not Implemented |
MI0247 # 06 Y:2013 | 06 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,908 | $2,520 | Implemented |
MI0247 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,525 | $1,660 | Implemented |
MI0247 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,027 | $8,010 | Implemented |
MI0247 # 03 Y:2013 | 03 | 2013 | INCREASE EFFICIENCY OF TRUCKS | $7,110 | $5,800 | Not Implemented |
MI0247 # 02 Y:2013 | 02 | 2013 | INSULATE BARE EQUIPMENT | $118,483 | $20,790 | Not Implemented |
MI0247 # 01 Y:2013 | 01 | 2013 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $630,378 | $1,000,000 | Not Implemented |
UF0423 # 09 Y:2009 | 09 | 2009 | RECYCLE FLUORESCENT LAMPS | $2,671 | $3,405 | Not Implemented |
UF0423 # 01 Y:2009 | 01 | 2009 | INSULATE BARE EQUIPMENT | $7,135 | $12,571 | Not Implemented |
UF0423 # 08 Y:2009 | 08 | 2009 | INSTALL OCCUPANCY SENSORS | $495 | $315 | Not Implemented |
UF0423 # 07 Y:2009 | 07 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,505 | $2,503 | Not Implemented |
UF0423 # 06 Y:2009 | 06 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $753 | $0 | Implemented |
UF0423 # 05 Y:2009 | 05 | 2009 | REDESIGN PROCESS | $206,074 | $300,000 | Not Implemented |
UF0423 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,606 | $38,839 | Not Implemented |
UF0423 # 03 Y:2009 | 03 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,442 | $600 | Implemented |
UF0423 # 02 Y:2009 | 02 | 2009 | USE OPTIMUM TEMPERATURE | $45,100 | $0 | Not Implemented |
UF0423 # 17 Y:2009 | 17 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $68,520 | $24,901 | Not Implemented |
UF0423 # 10 Y:2009 | 10 | 2009 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,109 | $283 | Not Implemented |
UF0423 # 11 Y:2009 | 11 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,767 | $1,301 | Implemented |
UF0423 # 12 Y:2009 | 12 | 2009 | INSULATE BARE EQUIPMENT | $159,410 | $5,591 | Not Implemented |
UF0423 # 13 Y:2009 | 13 | 2009 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,000 | $0 | Not Implemented |
UF0423 # 14 Y:2009 | 14 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $3,460 | $0 | Implemented |
UF0423 # 15 Y:2009 | 15 | 2009 | General | $8,403 | $1,164 | Not Implemented |
UF0423 # 16 Y:2009 | 16 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,288 | $506 | Not Implemented |
MI0120 # 02 Y:2006 | 02 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $145,490 | $5,540 | Not Implemented |