Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsNAICS | 324 | Petroleum and Coal Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0408 # 01 Y:2016 | 01 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $34,913 | $25 | Implemented |
LE0408 # 02 Y:2016 | 02 | 2016 | REPAIR OR REPLACE STEAM TRAPS | $28,076 | $1,125 | Implemented |
LE0408 # 03 Y:2016 | 03 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,093 | $1,000 | Implemented |
LE0408 # 04 Y:2016 | 04 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $190 | $25 | Not Implemented |
LE0408 # 05 Y:2016 | 05 | 2016 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $293,975 | $56,000 | Not Implemented |
LE0408 # 06 Y:2016 | 06 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,005 | $4,800 | Implemented |
LE0408 # 07 Y:2016 | 07 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,070 | $10,080 | Not Implemented |
LE0408 # 08 Y:2016 | 08 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $69,013 | $99,925 | Not Implemented |
LE0408 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,933 | $45,975 | Implemented |
DL0056 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,100 | $58,000 | Not Implemented |
DL0056 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,000 | $94,500 | Not Implemented |
DL0056 # 07 Y:2010 | 07 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,100 | $100 | Not Implemented |
DL0056 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM TEMPERATURE | $7,644 | $100 | Implemented |
DL0056 # 05 Y:2010 | 05 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,000 | $300 | Implemented |
DL0056 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $45,700 | $7,900 | Not Implemented |
DL0056 # 03 Y:2010 | 03 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $42,720 | $1,940 | Not Implemented |
DL0056 # 02 Y:2010 | 02 | 2010 | KEEP EQUIPMENT CLEAN | $162,929 | $102,000 | Not Implemented |
DL0056 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $184,560 | $1,200,000 | Implemented |
LE0204 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,784 | $600 | Not Implemented |
LE0204 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,339 | $6,000 | Not Implemented |
LE0204 # 03 Y:2005 | 03 | 2005 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $4,345 | $2,750 | Implemented |
LE0204 # 02 Y:2005 | 02 | 2005 | INSULATE FEEDWATER TANK | $18,286 | $8,304 | Implemented |
LE0204 # 01 Y:2005 | 01 | 2005 | BURN WASTE OIL FOR HEAT | $18,746 | $3,000 | Not Implemented |