Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

540

matching recommendations
Reset
NAICS 32412 Asphalt Paving, Roofing, and Saturated Materials Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0803 # 06 Y:2005 06 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,157 $27,000 Not Implemented
GT0803 # 07 Y:2005 07 2005 USE PHOTOCELL CONTROLS $2,516 $570 Implemented
GT0803 # 08 Y:2005 08 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $779 $695 Implemented
GT0803 # 09 Y:2005 09 2005 OPTIMIZE PLANT POWER FACTOR $17,969 $6,055 Not Implemented
LE0204 # 01 Y:2005 01 2005 BURN WASTE OIL FOR HEAT $18,746 $3,000 Not Implemented
LE0204 # 02 Y:2005 02 2005 INSULATE FEEDWATER TANK $18,286 $8,304 Implemented
LE0204 # 03 Y:2005 03 2005 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $4,345 $2,750 Implemented
LE0204 # 04 Y:2005 04 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,339 $6,000 Not Implemented
LE0204 # 05 Y:2005 05 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,784 $600 Not Implemented
UD0709 # 01 Y:2005 01 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $17,133 $0 Not Implemented
UD0709 # 02 Y:2005 02 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,549 $34,600 Not Implemented
UD0709 # 03 Y:2005 03 2005 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $13,847 $40,000 Not Implemented
UD0709 # 04 Y:2005 04 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,529 $0 Implemented
UD0709 # 05 Y:2005 05 2005 INSULATE BARE EQUIPMENT $3,977 $4,500 Implemented
UD0709 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,708 $3,213 Not Implemented
OR0472 # 01 Y:2004 01 2004 INSULATE BARE EQUIPMENT $20,400 $3,200 Implemented
OR0472 # 02 Y:2004 02 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,100 $3,300 Implemented
OR0472 # 03 Y:2004 03 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $5,173 $2,000 Implemented
OR0472 # 04 Y:2004 04 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,500 $38,000 Implemented
SF0293 # 01 Y:2004 01 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,290 $2,477 Not Implemented
SF0293 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $656 $592 Implemented
SF0293 # 03 Y:2004 03 2004 USE PHOTOCELL CONTROLS $3,487 $4,892 Not Implemented
SF0293 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,002 $7,873 Implemented
SF0293 # 05 Y:2004 05 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,148 $16,468 Not Implemented
SF0293 # 06 Y:2004 06 2004 INSTALL OCCUPANCY SENSORS $1,527 $3,458 Not Implemented