IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

189

matching recommendations
Reset
NAICS 324191 Petroleum Lubricating Oil and Grease Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0830 # 01 Y:2006 01 2006 USE SYNTHETIC LUBRICANT $1,678 $0 Implemented
GT0830 # 02 Y:2006 02 2006 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $140,680 $87,010 Implemented
GT0830 # 03 Y:2006 03 2006 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $8,256 $36,000 Not Implemented
GT0830 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,756 $5,548 Implemented
GT0830 # 05 Y:2006 05 2006 REPAIR AND ELIMINATE STEAM LEAKS $9,422 $1,250 Not Implemented
GT0830 # 06 Y:2006 06 2006 CHECK FOR ACCURACY OF UTILITY / POWER METERS $1,790 $0 Not Implemented
GT0830 # 07 Y:2006 07 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,966 $4,500 Not Implemented
GT0830 # 08 Y:2006 08 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $918 $0 Implemented
GT0830 # 09 Y:2006 09 2006 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,744 $5,630 Not Implemented
TA0084 # 01 Y:2004 01 2004 REDUCE EXCESS STEAM BLEEDING $6,613 $0 Not Implemented
TA0084 # 02 Y:2004 02 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $4,480 $0 Not Implemented
TA0084 # 03 Y:2004 03 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $3,760 $1,150 Not Implemented
TA0084 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,090 $500 Not Implemented
TA0084 # 05 Y:2004 05 2004 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,360 $1,610 Not Implemented
TA0084 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $416 $10 Not Implemented
TA0084 # 07 Y:2004 07 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,235 $0 Not Implemented
TA0084 # 08 Y:2004 08 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $610 $230 Not Implemented
LL0172 # 01 Y:2003 01 2003 REPAIR AND ELIMINATE STEAM LEAKS $390,733 $195,000 Implemented
LL0172 # 02 Y:2003 02 2003 ELIMINATE COMBUSTIBLE GAS IN FLUE GAS $197,664 $250,000 Not Implemented
LL0172 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $101,833 $7,757 Not Implemented
LL0172 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $87,485 $28,240 Implemented
LL0172 # 05 Y:2003 05 2003 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $65,820 $312,701 Not Implemented
LL0172 # 06 Y:2003 06 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $21,972 $5,600 Implemented
LL0172 # 07 Y:2003 07 2003 INSULATE BARE EQUIPMENT $5,380 $682 Not Implemented
LL0172 # 08 Y:2003 08 2003 USE PHOTOCELL CONTROLS $3,809 $1,176 Not Implemented