Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
616
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0881 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $371 | $1,000 | Not Implemented |
UD0881 # 10 Y:2013 | 10 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,191 | $15,000 | Implemented |
UD0881 # 11 Y:2013 | 11 | 2013 | USE MINIMUM STEAM OPERATING PRESSURE | $184 | $200 | Implemented |
UD0881 # 12 Y:2013 | 12 | 2013 | IMPROVE COMBUSTION CONTROL CAPABILITY | $133 | $100 | Implemented |
UD0881 # 13 Y:2013 | 13 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $20,343 | $55,500 | Not Implemented |
UD0881 # 14 Y:2013 | 14 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,378 | $11,500 | Not Implemented |
UD0881 # 15 Y:2013 | 15 | 2013 | COVER OPEN TANKS | $3,707 | $3,174 | Not Implemented |
UD0881 # 16 Y:2013 | 16 | 2013 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $24,715 | $101,000 | Not Implemented |
UD0870 # 01 Y:2012 | 01 | 2012 | USE PHOTOCELL CONTROLS | $1,385 | $1,660 | Implemented |
UD0870 # 02 Y:2012 | 02 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $5,228 | $10,000 | Implemented |
UD0870 # 03 Y:2012 | 03 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,564 | $16,800 | Not Implemented |
UD0870 # 04 Y:2012 | 04 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,610 | $1,500 | Implemented |
UD0870 # 05 Y:2012 | 05 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,199 | $1,500 | Implemented |
UD0870 # 06 Y:2012 | 06 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $10,454 | $1,800 | Implemented |
UD0870 # 07 Y:2012 | 07 | 2012 | USE MINIMUM STEAM OPERATING PRESSURE | $7,517 | $0 | Implemented |
UD0870 # 08 Y:2012 | 08 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,567 | $4,000 | Not Implemented |
UD0870 # 09 Y:2012 | 09 | 2012 | ISOLATE HOT OR COLD EQUIPMENT | $1,602 | $4,000 | Not Implemented |
UD0870 # 10 Y:2012 | 10 | 2012 | INSULATE BARE EQUIPMENT | $1,512 | $0 | Implemented |
UD0870 # 11 Y:2012 | 11 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,788 | $3,000 | Implemented |
WV0448 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,725 | $9,258 | Implemented |
WV0448 # 02 Y:2012 | 02 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,053 | $51,600 | Not Implemented |
WV0448 # 03 Y:2012 | 03 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,859 | $16,925 | Not Implemented |
WV0448 # 04 Y:2012 | 04 | 2012 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $3,243 | $14,500 | Not Implemented |
WV0448 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $1,979 | $1,826 | Implemented |
WV0448 # 06 Y:2012 | 06 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $1,968 | $10,438 | Not Implemented |