Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
126
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0493 # 08 Y:2014 | 08 | 2014 | INSULATE BARE EQUIPMENT | $3,507 | $1,251 | Implemented |
WV0493 # 09 Y:2014 | 09 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,643 | $15 | Implemented |
WV0493 # 10 Y:2014 | 10 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,071 | $1,000 | Not Implemented |
WV0493 # 11 Y:2014 | 11 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $1,391 | $661 | Not Implemented |
WV0407 # 01 Y:2010 | 01 | 2010 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $622,016 | $798,300 | Not Implemented |
WV0407 # 02 Y:2010 | 02 | 2010 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $542,540 | $1,200,000 | Not Implemented |
WV0407 # 03 Y:2010 | 03 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $235,631 | $5,500 | Implemented |
WV0407 # 04 Y:2010 | 04 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $43,962 | $96,200 | Not Implemented |
WV0407 # 05 Y:2010 | 05 | 2010 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $20,301 | $7,920 | Not Implemented |
WV0407 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,102 | $43,400 | Not Implemented |
WV0407 # 07 Y:2010 | 07 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $10,842 | $772 | Implemented |
WV0407 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,003 | $17,348 | Implemented |
WV0407 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,209 | $7,158 | Implemented |
WV0407 # 10 Y:2010 | 10 | 2010 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,353 | $1,000 | Implemented |
WV0397 # 01 Y:2009 | 01 | 2009 | REDUCE VENTILATION AIR | $153,645 | $145,000 | Not Implemented |
WV0397 # 02 Y:2009 | 02 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $81,057 | $131,239 | Not Implemented |
WV0397 # 03 Y:2009 | 03 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $77,885 | $17,000 | Not Implemented |
WV0397 # 04 Y:2009 | 04 | 2009 | OPERATE BOILERS ON HIGH FIRE SETTING | $56,916 | $80,000 | Not Implemented |
WV0397 # 05 Y:2009 | 05 | 2009 | OPTIMIZE PLANT POWER FACTOR | $40,984 | $44,000 | Not Implemented |
WV0397 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,130 | $36,900 | Not Implemented |
WV0397 # 07 Y:2009 | 07 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,728 | $0 | Implemented |
WV0397 # 08 Y:2009 | 08 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,726 | $1,000 | Implemented |
WV0397 # 09 Y:2009 | 09 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,377 | $49,300 | Not Implemented |
WV0397 # 10 Y:2009 | 10 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $7,120 | $5,500 | Implemented |
WV0397 # 11 Y:2009 | 11 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,792 | $19,960 | Implemented |