Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,503
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0204 # 07 Y:2018 | 07 | 2018 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $968 | $0 | Implemented |
TT0204 # 08 Y:2018 | 08 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $637 | $675 | Implemented |
TT0204 # 09 Y:2018 | 09 | 2018 | INSTALL TIMERS AND/OR THERMOSTATS | $402 | $0 | Implemented |
WM0115 # 01 Y:2017 | 01 | 2017 | USE SYNTHETIC LUBRICANT | $11,231 | $17,756 | Not Implemented |
WM0115 # 02 Y:2017 | 02 | 2017 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $7,812 | $810 | Not Implemented |
WM0115 # 03 Y:2017 | 03 | 2017 | USE SOLAR HEAT TO MAKE ELECTRICTY | $7,532 | $17,600 | Not Implemented |
WM0115 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,509 | $3,740 | Not Implemented |
WM0115 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $212 | $550 | Not Implemented |
AS0447 # 01 Y:2017 | 01 | 2017 | INSTALL SKYLIGHTS | $2,950 | $11,772 | Not Implemented |
AS0447 # 02 Y:2017 | 02 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,627 | $26,290 | Not Implemented |
AS0447 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $827 | $80 | Implemented |
AS0447 # 04 Y:2017 | 04 | 2017 | SELL COMBUSTIBLE WASTE | $32,800 | $9 | Not Implemented |
NC0605 # 01 Y:2017 | 01 | 2017 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $23,044 | $93,000 | Not Implemented |
NC0605 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,828 | $10,328 | Implemented |
NC0605 # 03 Y:2017 | 03 | 2017 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $118 | $50 | Implemented |
NC0605 # 04 Y:2017 | 04 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $812 | $1,000 | Not Implemented |
NC0605 # 05 Y:2017 | 05 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $685 | $2,000 | Implemented |
NC0605 # 06 Y:2017 | 06 | 2017 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $65,888 | $500 | Implemented |
NC0605 # 07 Y:2017 | 07 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $3,455 | $11,302 | Implemented |
UF0512 # 01 Y:2017 | 01 | 2017 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $401,159 | $2,500,000 | Not Implemented |
UF0512 # 02 Y:2017 | 02 | 2017 | ISOLATE HOT OR COLD EQUIPMENT | $124,880 | $17,000 | Implemented |
UF0512 # 03 Y:2017 | 03 | 2017 | OPTIMIZE PLANT POWER FACTOR | $38,189 | $13,000 | Implemented |
UF0512 # 04 Y:2017 | 04 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $23,030 | $40,000 | Not Implemented |
UF0512 # 05 Y:2017 | 05 | 2017 | USE CORRECT SIZE STEAM TRAPS | $27,893 | $340 | Implemented |
UF0512 # 06 Y:2017 | 06 | 2017 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $10,845 | $2,750 | Implemented |