Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
275
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0264 # 09 Y:2007 | 09 | 2007 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,674 | $5,000 | Not Implemented |
LE0264 # 10 Y:2007 | 10 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,288 | $1,000 | Implemented |
LE0264 # 11 Y:2007 | 11 | 2007 | INSTALL OCCUPANCY SENSORS | $3,069 | $750 | Not Implemented |
LE0259 # 01 Y:2007 | 01 | 2007 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,497 | $7,000 | Not Implemented |
LE0259 # 02 Y:2007 | 02 | 2007 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $15,235 | $500 | Implemented |
LE0259 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,283 | $45,000 | Implemented |
LE0259 # 04 Y:2007 | 04 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,735 | $37,000 | Implemented |
LE0259 # 05 Y:2007 | 05 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,811 | $200 | Implemented |
LE0259 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,501 | $50 | Not Implemented |
LE0259 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,938 | $4,386 | Not Implemented |
LE0247 # 01 Y:2006 | 01 | 2006 | REPLACE BOILER | $115,080 | $223,000 | Not Implemented |
LE0247 # 02 Y:2006 | 02 | 2006 | REVISE RAW MATERIAL SPECS | $106,250 | $60,000 | Not Implemented |
LE0247 # 03 Y:2006 | 03 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $26,312 | $16,000 | Not Implemented |
LE0247 # 04 Y:2006 | 04 | 2006 | ADOPT IN-HOUSE MATERIAL GENERATION | $24,012 | $20,000 | Implemented |
LE0247 # 05 Y:2006 | 05 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,245 | $15,000 | Not Implemented |
LE0247 # 06 Y:2006 | 06 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,646 | $2,500 | Implemented |
LE0247 # 07 Y:2006 | 07 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,225 | $1,152 | Implemented |
LE0247 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $1,181 | $300 | Not Implemented |
LE0247 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,912 | $3,722 | Not Implemented |
WV0346 # 01 Y:2006 | 01 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $12,230 | $1,143 | Implemented |
WV0346 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,998 | $13,688 | Implemented |
WV0346 # 03 Y:2006 | 03 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $4,996 | $8,800 | Not Implemented |
WV0346 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,442 | $4,540 | Not Implemented |
WV0346 # 05 Y:2006 | 05 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,952 | $656 | Not Implemented |
WV0346 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $1,502 | $737 | Implemented |