Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

22

matching recommendations
Reset
NAICS 325 Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1613 # 02 Y:2017 02 2017 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,671 $0 Implemented
UK1613 # 06 Y:2017 06 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,264 $1,200 Implemented
UK1613 # 07 Y:2017 07 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $871 $0 Implemented
UK1613 # 08 Y:2017 08 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $535 $0 Implemented
UK1613 # 09 Y:2017 09 2017 USE ONLY CERTIFIED MOTOR REPAIR SHOPS $478 $756 Implemented
UK1613 # 10 Y:2017 10 2017 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $145 $0 Implemented
UK1603 # 10 Y:2016 10 2016 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $2,457 $0 Implemented
UK1603 # 09 Y:2016 09 2016 PREHEAT COMBUSTION AIR WITH WASTE HEAT $33,165 $58,682 Implemented
UK1603 # 01 Y:2016 01 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $89,730 $85,358 Implemented
UK1603 # 03 Y:2016 03 2016 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $18,272 $35,000 Implemented
UK1603 # 04 Y:2016 04 2016 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $9,160 $14,700 Implemented
UK1603 # 06 Y:2016 06 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,304 $1,600 Implemented
UK1603 # 07 Y:2016 07 2016 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $16,948 $0 Implemented
UK1317 # 02 Y:2013 02 2013 OPTIMIZE PLANT POWER FACTOR $11,706 $17,700 Implemented
UK1317 # 06 Y:2013 06 2013 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $3,200 $1,900 Implemented
UK1317 # 01 Y:2013 01 2013 RECOVER WASTE HEAT FROM EQUIPMENT $139,142 $342,000 Implemented
UD0873 # 01 Y:2013 01 2013 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $8,346 $0 Implemented
UD0873 # 02 Y:2013 02 2013 OPTIMIZE PLANT POWER FACTOR $1,443 $2,400 Implemented
UD0873 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,732 $9,904 Implemented
UD0873 # 05 Y:2013 05 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $680 $1,050 Implemented
UD0873 # 07 Y:2013 07 2013 USE RADIANT HEATER FOR SPOT HEATING $1,809 $0 Implemented
UD0873 # 08 Y:2013 08 2013 RECOVER WASTE HEAT FROM EQUIPMENT $23,496 $50,000 Implemented