Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
220
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0397 # 09 Y:2009 | 09 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,377 | $49,300 | Not Implemented |
WV0397 # 03 Y:2009 | 03 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $77,885 | $17,000 | Not Implemented |
WV0397 # 05 Y:2009 | 05 | 2009 | OPTIMIZE PLANT POWER FACTOR | $40,984 | $44,000 | Not Implemented |
WV0397 # 02 Y:2009 | 02 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $81,057 | $131,239 | Not Implemented |
WV0397 # 04 Y:2009 | 04 | 2009 | OPERATE BOILERS ON HIGH FIRE SETTING | $56,916 | $80,000 | Not Implemented |
WV0397 # 10 Y:2009 | 10 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $7,120 | $5,500 | Implemented |
WV0397 # 11 Y:2009 | 11 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,792 | $19,960 | Implemented |
WV0397 # 08 Y:2009 | 08 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,726 | $1,000 | Implemented |
WV0397 # 01 Y:2009 | 01 | 2009 | REDUCE VENTILATION AIR | $153,645 | $145,000 | Not Implemented |
WV0397 # 07 Y:2009 | 07 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,728 | $0 | Implemented |
WV0397 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,130 | $36,900 | Not Implemented |
UM0359 # 09 Y:2009 | 09 | 2009 | INSTALL OCCUPANCY SENSORS | $1,161 | $30,000 | Implemented |
UM0359 # 06 Y:2009 | 06 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,724 | $7,574 | Not Implemented |
UM0359 # 04 Y:2009 | 04 | 2009 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $11,980 | $9,000 | Not Implemented |
UM0359 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,026 | $50,000 | Implemented |
UM0359 # 08 Y:2009 | 08 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,620 | $10,000 | Implemented |
UM0359 # 05 Y:2009 | 05 | 2009 | INSTALL STORM WINDOWS AND DOORS | $6,298 | $24,510 | Implemented |
UM0359 # 03 Y:2009 | 03 | 2009 | LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION | $13,963 | $400 | Implemented |
UM0359 # 10 Y:2009 | 10 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $472 | $10,000 | Implemented |
UM0359 # 07 Y:2009 | 07 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,630 | $5,000 | Not Implemented |
UM0359 # 01 Y:2009 | 01 | 2009 | REDUCE VENTILATION AIR | $20,146 | $500 | Implemented |
MZ0042 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $905 | $905 | Not Implemented |
MZ0042 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,970 | $214,200 | Not Implemented |
MZ0042 # 05 Y:2009 | 05 | 2009 | CONDENSE OPERATION INTO ONE BUILDING | $543,300 | $150,000 | Implemented |
MZ0042 # 02 Y:2009 | 02 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $19,660 | $18,000 | Not Implemented |