IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

995

matching recommendations
Reset
NAICS 3251 Basic Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0180 # 03 Y:2009 03 2009 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $7,931 $10,320 Not Implemented
MI0180 # 04 Y:2009 04 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,220 $1,210 Implemented
MI0180 # 05 Y:2009 05 2009 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $3,302 $4,531 Not Implemented
MI0180 # 06 Y:2009 06 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $310 $40 Implemented
LL0313 # 01 Y:2009 01 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $131,164 $15,480 Not Implemented
LL0313 # 02 Y:2009 02 2009 INSULATE BARE EQUIPMENT $16,960 $2,380 Not Implemented
LL0313 # 03 Y:2009 03 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,891 $2,500 Not Implemented
LL0313 # 04 Y:2009 04 2009 INSTALL OCCUPANCY SENSORS $1,563 $7,800 Not Implemented
LL0313 # 05 Y:2009 05 2009 INSTALL OCCUPANCY SENSORS $425 $330 Not Implemented
LL0313 # 06 Y:2009 06 2009 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $316 $270 Not Implemented
OK0773 # 01 Y:2009 01 2009 OPERATE BOILERS ON HIGH FIRE SETTING $14,770 $22,000 Not Implemented
OK0773 # 02 Y:2009 02 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,800 $0 Implemented
OK0773 # 03 Y:2009 03 2009 REPAIR AND ELIMINATE STEAM LEAKS $36,076 $2,450 Implemented
OK0773 # 04 Y:2009 04 2009 USE PHOTOCELL CONTROLS $1,554 $1,284 Implemented
OK0773 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $201 $1,887 Implemented
OK0773 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $81 $425 Implemented
IC0153 # 01 Y:2009 01 2009 INSTALL OCCUPANCY SENSORS $1,078 $642 Not Implemented
IC0153 # 02 Y:2009 02 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $206 $0 Not Implemented
IC0153 # 03 Y:2009 03 2009 USE SOLAR HEAT TO HEAT WATER $605 $2,240 Not Implemented
OR0540 # 01 Y:2008 01 2008 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $29 $10,000 Implemented
OR0540 # 02 Y:2008 02 2008 INCREASE AMOUNT OF CONDENSATE RETURNED $14,149 $6,100 Implemented
OR0540 # 03 Y:2008 03 2008 INSTALL OCCUPANCY SENSORS $2,932 $13,049 Implemented
OR0540 # 04 Y:2008 04 2008 USE SOLAR HEAT TO MAKE ELECTRICTY $23,433 $257,380 Not Implemented
OR0540 # 05 Y:2008 05 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $434 $12,400 Not Implemented
OR0540 # 06 Y:2008 06 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,216 $0 Not Implemented