Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
369
matching recommendationsNAICS | 32518 | Other Basic Inorganic Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0558 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,420 | $456 | Implemented |
UF0558 # 01 Y:2020 | 01 | 2020 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,597 | $19,045 | Implemented |
WV0599 # 14 Y:2020 | 14 | 2020 | INSULATE BARE EQUIPMENT | $361 | $1,123 | Implemented |
WV0599 # 10 Y:2020 | 10 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,356 | $21,400 | Implemented |
WV0599 # 09 Y:2020 | 09 | 2020 | IMPROVE COMBUSTION CONTROL CAPABILITY | $9,278 | $8,650 | Not Implemented |
WV0599 # 08 Y:2020 | 08 | 2020 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $10,828 | $39,480 | Not Implemented |
WV0599 # 07 Y:2020 | 07 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,054 | $14,700 | Implemented |
WV0599 # 06 Y:2020 | 06 | 2020 | DEVELOP A REPAIR/REPLACE POLICY | $13,389 | $2,433 | Not Implemented |
WV0599 # 05 Y:2020 | 05 | 2020 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,981 | $2,000 | Implemented |
WV0599 # 04 Y:2020 | 04 | 2020 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,379 | $45,860 | Implemented |
WV0599 # 03 Y:2020 | 03 | 2020 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $25,793 | $83,200 | Implemented |
WV0599 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50,634 | $94,500 | Implemented |
WV0599 # 01 Y:2020 | 01 | 2020 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $126,151 | $250,000 | Not Implemented |
WV0599 # 11 Y:2020 | 11 | 2020 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $4,587 | $27,500 | Not Implemented |
WV0599 # 12 Y:2020 | 12 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,517 | $2,256 | Implemented |
WV0599 # 13 Y:2020 | 13 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,644 | $1,250 | Implemented |
LE0485 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,410 | $17,950 | Not Implemented |
LE0485 # 06 Y:2019 | 06 | 2019 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $28,883 | $60,000 | Not Implemented |
LE0485 # 05 Y:2019 | 05 | 2019 | REPLACE BOILER | $162,332 | $344,000 | Not Implemented |
LE0485 # 04 Y:2019 | 04 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,784 | $9,200 | Not Implemented |
LE0485 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,180 | $2,250 | Not Implemented |
LE0485 # 02 Y:2019 | 02 | 2019 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $22,930 | $7,500 | Not Implemented |
LE0485 # 01 Y:2019 | 01 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,517 | $120 | Not Implemented |
OK1015 # 01 Y:2019 | 01 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,383 | $12,752 | Not Implemented |
OK1015 # 02 Y:2019 | 02 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,577 | $17,500 | Not Implemented |