IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

413

matching recommendations
Reset
NAICS 32519 Other Basic Organic Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0058 # 06 Y:2003 06 2003 INSTALL OCCUPANCY SENSORS $190 $123 Not Implemented
TA0058 # 07 Y:2003 07 2003 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $155 $0 Implemented
TA0058 # 08 Y:2003 08 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $214 $120 Not Implemented
IC0060 # 01 Y:2003 01 2003 REPAIR AND ELIMINATE STEAM LEAKS $148,006 $13,000 Implemented
IC0060 # 02 Y:2003 02 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $8,832 $13,240 Implemented
IC0060 # 03 Y:2003 03 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,390 $20,640 Implemented
IC0060 # 04 Y:2003 04 2003 USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) $163,590 $170,491 Implemented
IC0060 # 05 Y:2003 05 2003 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $92,294 $190,000 Not Implemented
IC0060 # 06 Y:2003 06 2003 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $9,196 $22,867 Not Implemented
IC0060 # 07 Y:2003 07 2003 REPAIR AND ELIMINATE STEAM LEAKS $11,372 $5,850 Implemented
IC0060 # 08 Y:2003 08 2003 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $7,439 $6,850 Not Implemented
IC0060 # 09 Y:2003 09 2003 RECOVER WASTE HEAT FROM EQUIPMENT $17,626 $13,998 Implemented
IC0060 # 10 Y:2003 10 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,705 $11,354 Implemented