Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
360
matching recommendationsNAICS | 325199 | All Other Basic Organic Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0407 # 04 Y:2010 | 04 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $43,962 | $96,200 | Not Implemented |
WV0407 # 03 Y:2010 | 03 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $235,631 | $5,500 | Implemented |
WV0407 # 02 Y:2010 | 02 | 2010 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $542,540 | $1,200,000 | Not Implemented |
WV0407 # 01 Y:2010 | 01 | 2010 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $622,016 | $798,300 | Not Implemented |
UF0432 # 10 Y:2010 | 10 | 2010 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $3,120 | $0 | Not Implemented |
UF0432 # 11 Y:2010 | 11 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,637 | $1,500 | Not Implemented |
UF0432 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,739 | $32,047 | Not Implemented |
UF0432 # 02 Y:2010 | 02 | 2010 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $4,188 | $5,591 | Not Implemented |
UF0432 # 03 Y:2010 | 03 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,940 | $2,240 | Not Implemented |
UF0432 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,539 | $719 | Not Implemented |
UF0432 # 05 Y:2010 | 05 | 2010 | USE PHOTOCELL CONTROLS | $6,416 | $768 | Not Implemented |
UF0432 # 06 Y:2010 | 06 | 2010 | INSTALL COMMON HEADER ON COMPRESSORS | $1,520 | $0 | Not Implemented |
UF0432 # 07 Y:2010 | 07 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,000 | $2,700 | Not Implemented |
UF0432 # 08 Y:2010 | 08 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $364 | $0 | Not Implemented |
UF0432 # 09 Y:2010 | 09 | 2010 | CLEAN CONDENSER TUBES | $1,343 | $120 | Not Implemented |
IC0153 # 01 Y:2009 | 01 | 2009 | INSTALL OCCUPANCY SENSORS | $1,078 | $642 | Not Implemented |
IC0153 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $206 | $0 | Not Implemented |
IC0153 # 03 Y:2009 | 03 | 2009 | USE SOLAR HEAT TO HEAT WATER | $605 | $2,240 | Not Implemented |
OR0540 # 01 Y:2008 | 01 | 2008 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $29 | $10,000 | Implemented |
OR0540 # 02 Y:2008 | 02 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $14,149 | $6,100 | Implemented |
OR0540 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $2,932 | $13,049 | Implemented |
OR0540 # 04 Y:2008 | 04 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $23,433 | $257,380 | Not Implemented |
OR0540 # 05 Y:2008 | 05 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $434 | $12,400 | Not Implemented |
OR0540 # 06 Y:2008 | 06 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,216 | $0 | Not Implemented |
OR0540 # 07 Y:2008 | 07 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $699 | $1,398 | Not Implemented |