IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

148

matching recommendations
Reset
NAICS 3252 Resin, Synthetic Rubber, and Artificial Synthetic Fibers and Filaments Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0422 # 09 Y:2011 09 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $954 $363 Implemented
WV0422 # 10 Y:2011 10 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $750 $329 Not Implemented
WV0400 # 01 Y:2010 01 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $104,233 $15,269 Implemented
WV0400 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28,861 $27,401 Implemented
WV0400 # 03 Y:2010 03 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $15,520 $7,000 Implemented
WV0400 # 04 Y:2010 04 2010 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $10,016 $5,000 Not Implemented
WV0400 # 05 Y:2010 05 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,436 $24,000 Not Implemented
WV0400 # 06 Y:2010 06 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,119 $10,100 Implemented
WV0400 # 07 Y:2010 07 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $7,115 $4,520 Implemented
WV0400 # 08 Y:2010 08 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,554 $3,700 Not Implemented
WV0400 # 09 Y:2010 09 2010 USE RADIANT HEATER FOR SPOT HEATING $6,252 $9,080 Not Implemented
WV0400 # 10 Y:2010 10 2010 DEVELOP A REPAIR/REPLACE POLICY $4,903 $2,278 Implemented
WV0400 # 11 Y:2010 11 2010 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $4,862 $2,300 Implemented
WV0400 # 12 Y:2010 12 2010 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $4,744 $2,000 Implemented
WV0400 # 13 Y:2010 13 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,843 $7,688 Implemented
WV0400 # 14 Y:2010 14 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,991 $1,713 Implemented
WV0400 # 15 Y:2010 15 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,177 $1,575 Not Implemented
WV0400 # 16 Y:2010 16 2010 IMPROVE LUBRICATION PRACTICES $2,060 $1,868 Not Implemented
WV0400 # 17 Y:2010 17 2010 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,611 $1,890 Not Implemented
UD0767 # 01 Y:2007 01 2007 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $30,284 $1,500 Implemented
UD0767 # 02 Y:2007 02 2007 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $20,419 $17,235 Not Implemented
UD0767 # 03 Y:2007 03 2007 UPGRADE CONTROLS ON COMPRESSORS $14,876 $0 Not Implemented
UD0767 # 04 Y:2007 04 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,731 $33,190 Not Implemented
UD0767 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,309 $7,740 Not Implemented
UD0767 # 06 Y:2007 06 2007 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $2,922 $5,000 Not Implemented