Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

115

matching recommendations
Reset
NAICS 32522 Artificial and Synthetic Fibers and Filaments Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0360 # 01 Y:2010 01 2010 RECOVER WASTE HEAT FROM EQUIPMENT $244,785 $930,000 Not Implemented
MS0360 # 02 Y:2010 02 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $91,795 $240,500 Implemented
MS0360 # 03 Y:2010 03 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,606 $18,481 Not Implemented
MS0362 # 01 Y:2010 01 2010 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $129,172 $586,857 Implemented
UA0048 # 01 Y:2010 01 2010 USE RADIANT HEATER FOR SPOT HEATING $8,059 $4,878 Not Implemented
UA0048 # 02 Y:2010 02 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $486 $0 Implemented
UA0048 # 03 Y:2010 03 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $6,421 $0 Implemented
UA0048 # 04 Y:2010 04 2010 INSTALL OCCUPANCY SENSORS $3,976 $728 Implemented
UA0048 # 05 Y:2010 05 2010 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,545 $0 Implemented
UA0048 # 06 Y:2010 06 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,450 $0 Not Implemented
UA0048 # 07 Y:2010 07 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,230 $2,000 Implemented
OK0751 # 01 Y:2007 01 2007 RECOVER WASTE HEAT FROM EQUIPMENT $2,572 $2,401 Not Implemented
OK0751 # 02 Y:2007 02 2007 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $59,692 $201,700 Not Implemented
OK0751 # 03 Y:2007 03 2007 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,188 $200 Not Implemented
LL0279 # 01 Y:2007 01 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $132,215 $49,640 Implemented
LL0279 # 02 Y:2007 02 2007 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $25,889 $5,250 Not Implemented
LL0279 # 03 Y:2007 03 2007 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $24,724 $40,000 Not Implemented
LL0279 # 04 Y:2007 04 2007 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,145 $2,490 Not Implemented
LL0279 # 05 Y:2007 05 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,945 $3,767 Not Implemented
LL0279 # 06 Y:2007 06 2007 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,535 $30 Not Implemented
LL0279 # 07 Y:2007 07 2007 INSTALL OCCUPANCY SENSORS $1,451 $840 Not Implemented
LL0279 # 08 Y:2007 08 2007 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,151 $1,580 Not Implemented
UF0392 # 01 Y:2006 01 2006 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $32,112 $2,775 Implemented
UF0392 # 02 Y:2006 02 2006 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $28,316 $138,000 Not Implemented
UF0392 # 03 Y:2006 03 2006 INSTALL OCCUPANCY SENSORS $238 $228 Not Implemented