Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
59
matching recommendationsNAICS | 32531 | Fertilizer Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0703 # 02 Y:2016 | 02 | 2016 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $24,300 | $11,400 | Implemented |
AM0703 # 05 Y:2016 | 05 | 2016 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $3,830 | $1,000 | Implemented |
AM0703 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,480 | $445 | Implemented |
AM0703 # 03 Y:2016 | 03 | 2016 | MOVE PRODUCT USING MECHANICAL MEANS | $23,300 | $66,600 | Implemented |
UD0911 # 05 Y:2014 | 05 | 2014 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $14,978 | $20,079 | Implemented |
UD0911 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,693 | $0 | Not Implemented |
UD0911 # 03 Y:2014 | 03 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,866 | $8,000 | Not Implemented |
UD0911 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,620 | $1,000 | Implemented |
UD0911 # 01 Y:2014 | 01 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,544 | $0 | Implemented |
UD0911 # 10 Y:2014 | 10 | 2014 | USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS | $262,802 | $80,000 | Not Implemented |
UD0911 # 06 Y:2014 | 06 | 2014 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $74,000 | $124,534 | Implemented |
UD0911 # 07 Y:2014 | 07 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,375 | $7,000 | Not Implemented |
UD0911 # 08 Y:2014 | 08 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,256 | $47,188 | Implemented |
UD0911 # 09 Y:2014 | 09 | 2014 | USE PHOTOCELL CONTROLS | $732 | $1,440 | Not Implemented |
MZ0119 # 01 Y:2013 | 01 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,963 | $0 | Implemented |
MZ0119 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,154 | $14,260 | Implemented |
MZ0119 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $1,150 | $900 | Implemented |
MZ0119 # 04 Y:2013 | 04 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,728 | $0 | Not Implemented |
UW0037 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,711 | $1,060 | Implemented |
UW0037 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $921 | $1,842 | Not Implemented |
UW0037 # 02 Y:2010 | 02 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $709 | $0 | Implemented |
MS0351 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,134 | $210 | Not Implemented |
MS0351 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $104,520 | $29,318 | Not Implemented |
MS0351 # 02 Y:2010 | 02 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $80,833 | $872 | Implemented |
MS0351 # 03 Y:2010 | 03 | 2010 | PAY UTILITY BILLS ON TIME | $36,706 | $0 | Implemented |