Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,078
matching recommendationsNAICS | 32541 | Pharmaceutical and Medicine Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0370 # 07 Y:2007 | 07 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $87,257 | $136,000 | Not Implemented |
NC0370 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $48,768 | $120,500 | Not Implemented |
NC0370 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,690 | $50 | Not Implemented |
NC0370 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,644 | $7,240 | Not Implemented |
IA0411 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,897 | $28,132 | Implemented |
IA0411 # 02 Y:2007 | 02 | 2007 | INSTALL OCCUPANCY SENSORS | $419 | $1,309 | Not Implemented |
IA0411 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $618 | $1,000 | Not Implemented |
IA0411 # 04 Y:2007 | 04 | 2007 | USE MINIMUM STEAM OPERATING PRESSURE | $833 | $150 | Not Implemented |
IA0411 # 05 Y:2007 | 05 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $911 | $1,275 | Not Implemented |
IA0411 # 06 Y:2007 | 06 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $17,816 | $1,375 | Not Implemented |
IA0411 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $441 | $410 | Not Implemented |
IA0411 # 08 Y:2007 | 08 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,675 | $33 | Implemented |
LE0259 # 01 Y:2007 | 01 | 2007 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,497 | $7,000 | Not Implemented |
LE0259 # 02 Y:2007 | 02 | 2007 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $15,235 | $500 | Implemented |
LE0259 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,283 | $45,000 | Implemented |
LE0259 # 04 Y:2007 | 04 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,735 | $37,000 | Implemented |
LE0259 # 05 Y:2007 | 05 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,811 | $200 | Implemented |
LE0259 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,501 | $50 | Not Implemented |
LE0259 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,938 | $4,386 | Not Implemented |
MS0318 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,453 | $34,528 | Implemented |
MS0318 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,884 | $20,897 | Implemented |
MS0318 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,013 | $401 | Implemented |
MS0318 # 04 Y:2007 | 04 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $2,805 | $156 | Implemented |
MS0318 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $747 | $378 | Not Implemented |
MS0318 # 06 Y:2007 | 06 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $587 | $0 | Implemented |