Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,078
matching recommendationsNAICS | 32541 | Pharmaceutical and Medicine Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NL0041 # 01 Y:2019 | 01 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $238,833 | $700,000 | Implemented |
NL0041 # 02 Y:2019 | 02 | 2019 | OPTIMIZE PLANT POWER FACTOR | $10,636 | $52,000 | Implemented |
NL0041 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,751 | $600 | Implemented |
NL0041 # 04 Y:2019 | 04 | 2019 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,670 | $100 | Implemented |
NL0041 # 05 Y:2019 | 05 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $5,000 | $19,750 | Implemented |
NL0041 # 06 Y:2019 | 06 | 2019 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $2,618 | $3,180 | Not Implemented |
NL0041 # 07 Y:2019 | 07 | 2019 | REPAIR AND ELIMINATE STEAM LEAKS | $2,123 | $200 | Implemented |
NL0041 # 08 Y:2019 | 08 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $197 | $674 | Implemented |
SU0491 # 01 Y:2019 | 01 | 2019 | DISCONNECT BALLASTS | $1,603 | $0 | Not Implemented |
SU0491 # 02 Y:2019 | 02 | 2019 | ELIMINATE/REDUCE AN OPERATION | $4,160 | $940 | Not Implemented |
SU0491 # 03 Y:2019 | 03 | 2019 | REDUCE VENTILATION AIR | $1,938 | $934 | Not Implemented |
SU0491 # 04 Y:2019 | 04 | 2019 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $405 | $542 | Not Implemented |
SU0491 # 05 Y:2019 | 05 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,086 | $1,842 | Not Implemented |
SU0491 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,429 | $102,442 | Not Implemented |
SU0491 # 07 Y:2019 | 07 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $385 | $1,387 | Not Implemented |
GT0934 # 01 Y:2019 | 01 | 2019 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,153 | $250 | Implemented |
GT0934 # 02 Y:2019 | 02 | 2019 | INSULATE BARE EQUIPMENT | $2,334 | $1,238 | Implemented |
GT0934 # 03 Y:2019 | 03 | 2019 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $9,210 | $19,899 | Not Implemented |
GT0934 # 04 Y:2019 | 04 | 2019 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $305,911 | $903,775 | Not Implemented |
GT0934 # 05 Y:2019 | 05 | 2019 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $445 | $2,770 | Implemented |
GT0934 # 06 Y:2019 | 06 | 2019 | USE SOLAR HEAT FOR HEAT | $37,938 | $246,597 | Implemented |
LE0482 # 01 Y:2019 | 01 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,428 | $1,040 | Implemented |
LE0482 # 02 Y:2019 | 02 | 2019 | REPAIR OR REPLACE STEAM TRAPS | $14,878 | $3,810 | Implemented |
LE0482 # 03 Y:2019 | 03 | 2019 | INSTALL TIMERS AND/OR THERMOSTATS | $215 | $70 | Not Implemented |
LE0482 # 04 Y:2019 | 04 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $35,019 | $27,273 | Not Implemented |