Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsNAICS | 32541 | Pharmaceutical and Medicine Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0411 # 07 Y:2005 | 07 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,150 | $991 | Not Implemented |
AS0411 # 06 Y:2005 | 06 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $4,077 | $8,000 | Implemented |
AS0411 # 05 Y:2005 | 05 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,783 | $11,000 | Not Implemented |
AS0411 # 04 Y:2005 | 04 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $6,515 | $10,000 | Not Implemented |
AS0411 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,306 | $1,000 | Implemented |
AS0411 # 02 Y:2005 | 02 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $18,100 | $1,500 | Not Implemented |
AS0411 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $56,988 | $21,600 | Not Implemented |
LE0221 # 01 Y:2005 | 01 | 2005 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $20,632 | $500 | Implemented |
LE0221 # 02 Y:2005 | 02 | 2005 | REDUCE VENTILATION AIR | $6,676 | $200 | Not Implemented |
LE0221 # 03 Y:2005 | 03 | 2005 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $4,200 | $200 | Not Implemented |
LE0221 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,761 | $6,000 | Not Implemented |
LE0221 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,628 | $500 | Not Implemented |
NC0321 # 03 Y:2005 | 03 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $19,559 | $3,000 | Implemented |
NC0321 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $60 | $179 | Not Implemented |
NC0321 # 02 Y:2005 | 02 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,185 | $5,475 | Implemented |
NC0321 # 01 Y:2005 | 01 | 2005 | USE AUTOMATIC CLEANING EQUIPMENT | $23,071 | $15,000 | Not Implemented |
NC0321 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $696 | $50 | Not Implemented |
NC0321 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,543 | $1,070 | Implemented |
CO0569 # 11 Y:2005 | 11 | 2005 | INSTALL OCCUPANCY SENSORS | $560 | $710 | Implemented |
CO0569 # 09 Y:2005 | 09 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,600 | $1,980 | Implemented |
CO0569 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,770 | $3,520 | Implemented |
CO0569 # 06 Y:2005 | 06 | 2005 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $17,660 | $106,080 | Not Implemented |
CO0569 # 05 Y:2005 | 05 | 2005 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $2,040 | $1,980 | Implemented |
CO0569 # 03 Y:2005 | 03 | 2005 | USE SOLAR HEAT TO HEAT WATER | $8,940 | $108,000 | Not Implemented |
CO0569 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,470 | $1,000 | Implemented |