Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
71
matching recommendationsNAICS | 32541 | Pharmaceutical and Medicine Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0397 # 07 Y:2009 | 07 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,728 | $0 | Implemented |
WV0397 # 04 Y:2009 | 04 | 2009 | OPERATE BOILERS ON HIGH FIRE SETTING | $56,916 | $80,000 | Not Implemented |
WV0397 # 02 Y:2009 | 02 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $81,057 | $131,239 | Not Implemented |
WV0397 # 11 Y:2009 | 11 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,792 | $19,960 | Implemented |
WV0397 # 03 Y:2009 | 03 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $77,885 | $17,000 | Not Implemented |
WV0397 # 08 Y:2009 | 08 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,726 | $1,000 | Implemented |
WV0397 # 10 Y:2009 | 10 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $7,120 | $5,500 | Implemented |
WV0397 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,130 | $36,900 | Not Implemented |
WV0397 # 09 Y:2009 | 09 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,377 | $49,300 | Not Implemented |
WV0397 # 05 Y:2009 | 05 | 2009 | OPTIMIZE PLANT POWER FACTOR | $40,984 | $44,000 | Not Implemented |
WV0397 # 01 Y:2009 | 01 | 2009 | REDUCE VENTILATION AIR | $153,645 | $145,000 | Not Implemented |
SF0378 # 01 Y:2009 | 01 | 2009 | ADJUST VENTS TO MINIMIZE ENERGY USE | $4,936 | $0 | Not Implemented |
SF0378 # 08 Y:2009 | 08 | 2009 | USE PHOTOCELL CONTROLS | $771 | $1,925 | Not Implemented |
SF0378 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $559 | $840 | Not Implemented |
SF0378 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $13,576 | $17,518 | Not Implemented |
SF0378 # 05 Y:2009 | 05 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $28,409 | $12,868 | Not Implemented |
SF0378 # 04 Y:2009 | 04 | 2009 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $396 | $75 | Not Implemented |
SF0378 # 03 Y:2009 | 03 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,063 | $500 | Implemented |
SF0378 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,697 | $0 | Implemented |
UD0803 # 16 Y:2009 | 16 | 2009 | DISCONNECT BALLASTS | $428 | $0 | Implemented |
UD0803 # 15 Y:2009 | 15 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $663 | $1,125 | Not Implemented |
UD0803 # 14 Y:2009 | 14 | 2009 | ISOLATE HOT OR COLD EQUIPMENT | $1,120 | $0 | Not Implemented |
UD0803 # 07 Y:2009 | 07 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,851 | $500 | Not Implemented |
UD0803 # 01 Y:2009 | 01 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $393,528 | $8,000 | Implemented |
UD0803 # 02 Y:2009 | 02 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $21,371 | $3,376 | Implemented |